PCM-L05S100-G23
16s Li-ion/LiFePO4 Batteries
130A
to Read Battery Data on APP
to Read Battery Data (Voltage, Current,etc)
to Read Battery Data
Share a Common Port
7-15 Working Days
L200*W98*T16mm
Yes
SmarTEC
Antistatic Bag
16S BMS For Li-ion/LiFePO4 battery pack
Shenzhen
8507909000
Product Description
4S 8S 16S PCB Lead-acid Replacement Battery for BMS intelligent management system
Iron Phosphate Battery/LiFePo4 battery pack protection circuit board with high/low temp. & 2 stages protection Function (12V 100AH 12V 120AH)
Support with 4S-5S chargeable Li-ion phosphate battery pack and LiFePo4 battery pack
| Part name: | PCM-L05S100-G23 | Size: | 200*98*16mm |
| Apply: | 12V 100Ah 12V 120Ah | Max. Cont.charge/discharge current: | 130 A |
Charge & discharge share a same common port | |||

Feature of PCB
With the balance function
with two stages discharge over current protection
with temp. switch to check the temp. of battery,control the MOSFET of discharge
High / low temp. protection for overcharge & over-discharge
with two stages discharge over current protection
with temp. switch to check the temp. of battery,control the MOSFET of discharge
High / low temp. protection for overcharge & over-discharge

Details Descrption
| Safety level | Min | Typical | Max | Delay | |
| Cell Overvoltage Protection | 1st Level Overvoltage | 3700mV | 3750mV | 3800mV | 0.8-2S |
| 1st Level Overvoltage release | 3400mV | 3500mV | 3600mV | 5S | |
| Cell Undervoltage Protection | 1st Level Undervoltage | 2150mV | 2200mV | 2250mV | 50-150mS |
| 1st Level Undervoltage release | 2600mV | 2700mV | 2800mV | 5S | |
| Overcurrent in Charge Protection | 1st Level Overcurrent charge | - | - | - | - |
| 1st Level Overcurrent release | - | - | - | - | |
| Overcurrent in Discharge Protection | 1st Level Overcurrent Discharge | 550A | 600A | 650A | 250-350mS |
| 1st Level Overcurrent release | - | - | - | - | |
| 2nd Level Overcurrent Discharge | 650A | 700A | 750A | 50-150mS | |
| 2nd Level Overcurrent release | - | - | - | - | |
| Short Circuit in Discharge Protection | 1st Level Short circuit protection | 100A | - | ≤ 600uS | turn off the Discharging FET |
| 1st Level Short circuit release |
| Balance | Balanced open voltage(Cell) | Balanced release voltage(Cell) | Balanced current(Cell) |
| 3.50V±0.050V | 3.50V±0.050V | 110±30mA | |
| Over temperature | Over charge temperature(Battery) | Under charge temperature(Battery) | Over temperature(MOSFET) |
| 55ºC±4ºC | 0ºC±4ºC | 90±4ºC | |
| Over charge temperature releas(Battery) | Under charge temperature releas(Battery) | Over temperature releas(MOSFET) | |
| 50ºC±4ºC | 5ºC±4ºC | 75±4ºC | |
| Over discharge temperature(Battery) | Under discharge temperature(Battery) | Detection delay time | |
| 65ºC±4ºC | -20ºC±4ºC | 3-6S | |
| Over discharge temperature releas(Battery) | Under discharge temperature releas(Battery) | ||
| 60ºC±4ºC | -15ºC±4ºC |
Frequently-used in LiFePo4 battery pack with 12V 100Ah,12V 200Ah,application widely cover the battery management system for power supply and energy storage in Marine, Rv, Golf-cart, Solar energy,medical and others.