S32B-3011BA
Diffuse Reflection Type Photoelectric Sensor
Digital Type
Aluminum Die Cast
SemiConductor
IP65
CCC
Non-Customized
AIMIQU
Carton
SemiConductor
China
8501200000
Product Description
New and Original SICK Safety laser scanner S32B-3011BA
Detailed technical data
Features
1) Depending on basic response time and multiple sampling.
Safety-related parameters
Functions
Interfaces
1) Availability depends on the configuration of the universal I/Os.
Electrical data
1) At 24 V DC without output load.
2) At 24 V DC including maximum output load.
Mechanical data
Ambient data
Other information






Detailed technical data
Features
| Sub product family | S300 Mini Standard |
| Application | Indoor |
| Protective field range | 3 m |
| Warning field range | 8 m (at 15 % reflectivity) |
| Distance measuring range | 30 m |
| Type of field set | Triple field sets |
| Number of field sets | 1 |
| Number of fields | 3 |
| Number of monitoring cases | 1 |
| Scanning angle | 270° |
| Resolution (can be configured) | 30 mm, 40 mm, 50 mm, 70 mm, 150 mm |
| Angular resolution | 0.5° |
| Response time | 80 ms 1) |
| Protective field supplement | 100 mm |
| Number of multiple samplings | 2 ... 16, configurable |
| Delay of automatic reset | 2 s ... 60 s, configurable |
Safety-related parameters
| Type | Type 3 (IEC 61496) |
| Safety integrity level | SIL 2 (IEC 61508) |
| Category | Category 3 (EN ISO 13849) |
| Performance level | PL d (EN ISO 13849) |
| PFHD (mean probability of a dangerous fail- ure per hour) | 8.0 x 10-8 |
| TM (mission time) | 20 years (EN ISO 13849) |
| Safe state in the event of a fault | At least one OSSD is in the OFF state. |
| Restart interlock | |
| External device monitoring (EDM) | |
| Multiple sampling | |
| Contour as a reference | |
| Measured data output | None |
| Connection type | Cable, 250 mm, with male connector M12, 8-pin |
| Universal I/Os | 2 |
| Inputs External device monitoring (EDM) Reset/restart Standby | 11) 11) 11) |
| Outputs Output signal switching devices (OSSDs) Outputs for warning field Reset required | 2 21) 11) |
| Configuration method | PC with CDS (Configuration and Diagnostic Software) |
| Configuration and diagnostics interface Transmission rate | RS-232 38.4 kBaud |
Electrical data
| Protection class | III (EN 50178, EN 60950) |
| Supply voltage Vs | 24 V DC (16.8 V DC ... 30 V DC) |
| Power consumption | ≤ 0.25 A 1) ≤ 1.35 A 2) |
2) At 24 V DC including maximum output load.
Mechanical data
| Dimensions (W x H x D) | 102 mm x 116 mm x 105 mm |
| Weight | 0.8 kg, without connecting cables |
| Housing material | Aluminum die cast |
| Housing color | RAL 1021 (yellow), RAL 9005 (black) |
| Optics cover material | Polycarbonate |
| Optics cover surface finish | Outside with scratch-resistant coating |
| Enclosure rating | IP65 (EN 60529) |
| Ambient operating temperature | -10 °C ... +50 °C |
| Storage temperature | -25 °C ... +50 °C |
| Vibration resistance Class | IEC 60068-2-6, IEC 60068-2-64, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3 5M1 (IEC 60721-3-5) |
| Shock resistance | IEC 60068-2-27, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3 |
| Class | 5M1 (IEC 60721-3-5) |
| Continuous shock | 50 m/s², 11 ms 100 m/s², 16 ms |
| Type of light | Pulsed laser diode |
| Wave length | 905 nm |
| Detectable remission factor | 1.8 % ... > 1,000 %, reflectors |
| Laser class | 1 (21 CFR 1040.10 and 1040.11, IEC 60825-1) |