LUT3-620
Thru-Beam Sensor
Switching Type
IP67
CE
Non-Customized
AIMIQU
Carton
Germany
8481100090
Product Description
LUT3-620 Luminescence Sensors SICK Sensor Intelligence
1) 2) 3) 4) 5)
6)
Limit values when operated in short-circuit protected network: max. 8 A.
May not exceed or fall below Uv tolerances.
Without load.
With light/dark ratio 1:1.
Signal transit time with resistive load.
Reference voltage DC 50 V.
1) Limit values when operated in short-circuit protected network: max. 8 A.
2) May not exceed or fall below Uv tolerances.
3) Without load.
4) With light/dark ratio 1:1.
5) Signal transit time with resistive load.
6) Reference voltage DC 50 V.
Ambient data
Classifications







Detailed technical data
Features
1) From leading edge of lens.
2) Average service life: 100,000 hat TU = +25 °C.
Mechanics/electronics
Features
| Dimensions (W x H x D) | 30.4 mm x 53 mm x 80 mm |
| Sensing distance | ≤ 20 mm 1) |
| Housing design | Large |
| Working range | 10 mm ... 35 mm |
| Light source | LED, UV 2) |
| Wave length | 375 nm |
| Light emission | Long side |
| Light spot size | 3 mm x 9 mm |
| Light spot direction | Vertical |
| Receiving filters | KV 418 (standard) |
| Receiving range | 450 nm ... 750 nm |
| Adjustment | Potentiometer |
| Output function | Light switching |
2) Average service life: 100,000 hat TU = +25 °C.
Mechanics/electronics
| Supply voltage | 12 V DC ... 30 V DC1) | |
| Ripple | < 2 Vpp | 2) |
| Current consumption | < 60 mA 3) | |
| Switching frequency | 1.5 kHz 4) | |
1) 2) 3) 4) 5)
6)
Limit values when operated in short-circuit protected network: max. 8 A.
May not exceed or fall below Uv tolerances.
Without load.
With light/dark ratio 1:1.
Signal transit time with resistive load.
Reference voltage DC 50 V.
| Response time | 350 µs 5) |
| Switching output | PNP, NPN |
| Switching output (voltage) | PNP: HIGH = VS- ≤ 3 V/ LOW = approx. 0 V NPN: HIGH = approx. UV/ LOW ≤ 2 V |
| Switching mode | Light switching |
| Output current Imax. | 100 mA |
| Connection type | Male connector M12, 4-pin |
| Protection class | II 6) |
| Circuit protection | UV connections, reverse polarity protected Output Q short-circuit protected Interference pulse suppression |
| Enclosure rating | IP67 |
| Weight | 400 g |
| Housing material | Metal, zinc diecast |
2) May not exceed or fall below Uv tolerances.
3) Without load.
4) With light/dark ratio 1:1.
5) Signal transit time with resistive load.
6) Reference voltage DC 50 V.
Ambient data
| Ambient operating temperature | -10 °C ... +55 °C |
| Ambient temperature, storage | -25 °C ... +75 °C |
| Shock load | According to IEC 60068 |
| UL File No. | NRKH.E181493 & NRKH7.E181493 |
| eCl@ss 5.0 | 27270908 |
| eCl@ss 5.1.4 | 27270908 |
| eCl@ss 6.0 | 27270908 |
| eCl@ss 6.2 | 27270908 |
| eCl@ss 7.0 | 27270908 |
| eCl@ss 8.0 | 27270908 |
| eCl@ss 8.1 | 27270908 |
| eCl@ss 9.0 | 27270908 |
| eCl@ss 10.0 | 27270908 |
| eCl@ss 11.0 | 27270908 |
| eCl@ss 12.0 | 27270908 |
| ETIM 5.0 | EC001822 |
| ETIM 6.0 | EC001822 |
| ETIM 7.0 | EC001822 |
| ETIM 8.0 | EC001822 |
| UNSPSC 16.0901 | 39121528 |