Wireless Load Cell for Test Water Bag
Professional Equipment
Stainless Steel
Adult
Life Saving Parts
Water Bag
1-50t
Water Bag for Crane
Yes If Required
Yes If Required
Accept
MATCHAU
Export Packing
IACS approved
Jiangsu, China
3926909090
Product Description
Wireless Load Cell for Test Water Bag,Digital Dynamometer with Shackles
SAFE OPERATION GUIDE:
1.Do not make lifts beyond rated load capacity of the dynamometer, shackle.
2.Do not perform overhead weighing. Stay clear when Dynamometer is in operation.
3. Do not perform weighing under strong wind condition which may cause incorrect reading.
4. Do not perform weighing under environment of temperature rapid changes in which may cause incorrect reading.
5. Do not attempt to open this Dynamometer, no user serviceable parts inside.
6. Do not remove wire rope stopper from hook. For safety reasons, always apply it.
7. Remove all loads from shackle or hook when not in used.
8. Before weighing, check and make sure that all hanging /load- receiving elements / devices are in good condition.
9. Check hook, shackle, safety pins, and latches periodically. Contact your dealer for parts replacement in case defect, deform or wearing is found.
10. Always lift loads v HZically.
Company Information
Model | Cap.(T) | Division Valve (kg) | A (mm) | B (mm) | C (mm) | D (mm) | φ (mm) | H (mm) | Material |
MC-SW6-01 | 1 | 0.5 | 245 | 112 | 37 | 190 | 43 | 335 | Aluminium Alloy |
MC-SW6-02 | 2 | 1 | 245 | 116 | 37 | 190 | 43 | 335 | |
MC-SW6-03 | 3 | 1 | 260 | 123 | 37 | 195 | 51 | 365 | |
MC-SW6-05 | 5 | 2 | 285 | 123 | 57 | 210 | 58 | 405 | |
MC-SW6-10 | 10 | 5 | 320 | 120 | 57 | 230 | 92 | 535 | Alloy Steel Stainless Steel |
MC-SW6-20 | 20 | 10 | 420 | 128 | 74 | 260 | 127 | 660 | |
MC-SW6-30 | 30 | 10 | 420 | 138 | 82 | 280 | 146 | 740 | |
MC-SW6-50 | 50 | 20 | 465 | 150 | 104 | 305 | 184 | 930 | |
MC-SW6-100 | 100 | 50 | 570 | 190 | 132 | 366 | 229 | 1230 | |
MC-SW6-200 | 200 | 100 | 725 | 265 | 183 | 440 | 280 | 1380 | |
MC-SW6R-250 | 250 | 100 | 800 | 300 | 200 | 500 | 305 | 1880 | |
MC-SW6R-300 | 300 | 200 | 875 | 345 | 200 | 500 | 305 | 1955 | |
MC-SW6R-500 | 500 | 200 | 930 | 570 | 200 | 500 | 305 | 2065 |
SAFE OPERATION GUIDE:
1.Do not make lifts beyond rated load capacity of the dynamometer, shackle.
2.Do not perform overhead weighing. Stay clear when Dynamometer is in operation.
3. Do not perform weighing under strong wind condition which may cause incorrect reading.
4. Do not perform weighing under environment of temperature rapid changes in which may cause incorrect reading.
5. Do not attempt to open this Dynamometer, no user serviceable parts inside.
6. Do not remove wire rope stopper from hook. For safety reasons, always apply it.
7. Remove all loads from shackle or hook when not in used.
8. Before weighing, check and make sure that all hanging /load- receiving elements / devices are in good condition.
9. Check hook, shackle, safety pins, and latches periodically. Contact your dealer for parts replacement in case defect, deform or wearing is found.
10. Always lift loads v HZically.
Company Information