Usage
Residential Elevators, Construction Hoist
Lift Drive / Actuation
Electric Motor
Lift Mechanism
Articulated Lift
Deceleration Device
With Deceleration Device
Specification
SC200/200BZ
Stable Speed and Frequency Inverter Sc200/200bz Double Cage Construction Hoist
- 1. Saving power,adjusting speed,stale on /off powe
- 2. Adopting PLC for better safety control.Lower mechanic depletion.
- 3. Frequency Inverter
Item | Unit | Item | Remark | Rated loading capacity | kg | 2×2000 | | Rated installation loading capacity | kg | 2×1000 | | Rated lifting capacity of suspension rod | kg | 200 | | Rated lifting speed | m/min | 0~63 | | Maximum lifting height | m | 150 | | Internal net dimensions (L*W*H) of suspension cage | m | 3.2×1.5×2.5 | | Power voltage | V | 380±5% /50Hz | | Control voltage | V | 220AC | | Motor power | kW | 2×3×18.5 | JC25% | Rated working current | A | 2×3×38.5 | | Power | kVA | 2×3×25 | | Capacity of main power fuse | A | 120 | | Mast section dimensions (L*W*H) | m | 0.65×0.65×1.508 | | Mast section weight (∮76*4.5) | kg | 145 | | Mast section weight (∮76*6.3) | kg | 165 | | Mast section weight (∮76*8.0) | kg | 180 | | Mast section weight (∮76*10.0) | kg | 198 | | Suspension cage weight (containing transmission mechanism) | kg | 2×2100 | | Whole machine weight | kg | 25000 | 150m | Anti-falling safety device | Model | / | SAJ40-1.2 | | Movement speed | m/s | 1.4 | | Ground clearance of suspension cage bottom plate in ground station | m | 0.7 | | Applicable ambient temperature range | °C | -20~40 | |
|