Product model:KT58-1454C
1.Electrical performance specifications & physical characteristics
4.Test conditions and instruments
5.Detection angle test diagram
6.Precautions
1. The product can only be used in the air, not in liquid
2. In order to prevent the sensor from failure, working failure or performance degradation, the anti failure function shall be added to the product design, and the product shall not be used under the following or similar conditions.
(a) strong shock or vibration
(b) prolonged exposure to high temperature and humidity;
(c)In corrosive gas or sea breeze
(d)Exposure to dissolved organic matter
(e)Dusty environment;
(f)Over allowable input voltage
7.Quality assurance
The sensor defects due to the manufacturer during the warranty period of the product can be replaced free of charge.
The following situations are not covered by the warranty.
1.Electrical performance specifications & physical characteristics
No. | Items | Standard and test condition |
1 | Function | Transmitter-Receiver |
2 | Center frequency(KHz) | 40.0±1.0(Piezoelectric impedance analyzer) |
3 | Sensitivity(us) | ≥200(normal temp test 0.8mΦ75mmPVC pipe) |
4 | Residual oscillation(ms) | <=1.68(Normal temp test including transmitting fundamental wave) |
5 | Capacitance(pF)(25ºC) | 1800±15% |
6 | Beam direction angle(deg)(º) | 100±15 |
50±15 | ||
7 | Ranging | >=0.8m(normal temp test Φ75mmPVC pipe) |
8 | Max Input Voltage(Vp-p) | 140 (pulse width 0.5ms, interval 10ms) |
9 | Operating Temperature (ºC) | -30~+80 |
10 | Storage Temperature (ºC) | -40~+85 |
11 | Terminal | XH2.54*2P Connector |
12 | Length(mm) | 2500±30mm customized |
13 | Weight(g) | 45 |
14 | Color | Customized |
15 | Outer shell material | Plastic |
2.Product picture
3. Environmental test
3. Environmental test
NO. | Items | Performance requirement |
1 | Center frequency (KHz) | 58±1.5KHz |
2 | Residual oscillation (ms) | 0.8-1.55ms |
3 | Distance(cm) | 1180-1220cm(Obstacle is φ 75pvc pipe) |
4 | Echo(us) | 150-450us |
5 | Capacitance (pF)(25ºC) | 1850±10pf |
6 | Max Allowable Input Voltage(Vp-p) | 140Vp-p |
7 | Beam direction angle(deg)(º) | Horizontal 100±15/ Vertical 50±15 |
8 | Function | Transmitter-Receiver |
9 | Storage Temperature (ºC) | -40~+80 |
10 | Operating Temperature (ºC) | -40~+85 |
11 | Color | Epoxy black |
Material | Appearance requirement | |
1 | Wire | The wire surface shall be free of scratches, deformation and damages; The waterproof female head shall be free of damages, flashing and deformation.The DC connector of the female head shall be in the middle without deviation |
2 | Sensor | The sensor surface shall be parallel to the rubber shell surface with no deviation. |
The sensor surface shall be free of paint droppings, sand points,concave points,scratches and dirt. |
No. | Items | Technical standard | Inspection records | Conclusion | ||||
1 | Center frequency | 58±1.5KHz | 59.1 | 57.7 | 59.2 | 59.2 | 57.9 | OK |
2 | Residual oscillation | 0.8-1.550ms | 1.32 | 1.25 | 1.28 | 1.32 | 1.31 | OK |
3 | Ranging | 1140-1220cm(Obstacle is φ75PVC pipe) | 1192 | 1193 | 1190 | 1191 | 1194 | OK |
4 | Echo | 150-450us | 187 | 192 | 202 | 195 | 263 | OK |
5 | Capacitance (25ºC) | 1660-2030pf | 1740 | 1730 | 1770 | 1770 | 1720 | OK |
6 | Beam direction angle | Horizontal 100±15° | 95 | 90 | 90 | 95 | 90 | OK |
Vertical 50±15° | 45 | 40 | 40 | 45 | 45 | OK | ||
No. | Material | Product appearance | ||||||
1 | Wire | No scratches, deformation or damages on the wire surface. No damages, flashing or deformation on the waterproof female head .The DC connector of the female head is in the middle without deviation | ||||||
2 | Sensor | The sensor surface is parallel to the rubber shell surface with no deviation.And no paint droppings, sand points,concave points,scratches or dirt on the surface. |
5.Detection angle test diagram
6.Precautions
1. The product can only be used in the air, not in liquid
2. In order to prevent the sensor from failure, working failure or performance degradation, the anti failure function shall be added to the product design, and the product shall not be used under the following or similar conditions.
(a) strong shock or vibration
(b) prolonged exposure to high temperature and humidity;
(c)In corrosive gas or sea breeze
(d)Exposure to dissolved organic matter
(e)Dusty environment;
(f)Over allowable input voltage
7.Quality assurance
The sensor defects due to the manufacturer during the warranty period of the product can be replaced free of charge.
The following situations are not covered by the warranty.
- improper use or handling by users.
- changed or repaired by the users.
- any other situation that does not belong to the responsibility of the manufacturer, such as natural disasters, accidents, etc.
Send Message