Model NO.
T370
Wiring Type
Four-Wire
Measuring Medium
Liquid
IP Rating
IP68
Certification
RoHS
Customized
Customized
Transport Package
Foam+Carton
Specification
dia. 19mm
Trademark
Runpaq
Origin
China
Type:
Piezoresistive Pressure Sensor
Component:
SemiConductor Type
For:
Diffused Silicon Pressure Transmitter
Output Signal Type:
Analog Type
Production Process:
Integration
Material:
Stainless Steel
Absolute Pressure Transmitter Piezoresistive Silicon Die Pressure Sensor For Atmospheric Measurement
T370 line AP transmitter references to the absolute (vacuum) pressure. The product covers all the constructions and output connections of the company.
1. Absolute Pressure (PABS)=Relative Pressure(Pg)+Atmospheric Pressure(B),
2. Vacuum Degree(Kv)=Atmospheric pressure(B)-Absolute pressure (PABS),Kv=B-PABS, (B>PABS)
Wiring diagrams
Dimensions
Wiring diagrams
Standard range
Notes: G for Gauge pressure; A for Absolute pressure; D for Differential pressure; S for Sealed gauge.
Model selections
T370 line AP transmitter references to the absolute (vacuum) pressure. The product covers all the constructions and output connections of the company.
1. Absolute Pressure (PABS)=Relative Pressure(Pg)+Atmospheric Pressure(B),
2. Vacuum Degree(Kv)=Atmospheric pressure(B)-Absolute pressure (PABS),Kv=B-PABS, (B>PABS)
Application | Key features |
• Atmospheric measurements • Aerospace • Packaging machinery • Petrochemicals • Weather monitoring • Automatic detection system • Wind pressure measurement • High-rise building management | • Pressure type: Absolute Pressure • Range: any pressure between 0.01MPa~40MPa • Accuracy: ±0.25%F.S, ±0.5%F.S • Stability0.25%F.S/Year(typical), 0.4%F.S/Year(maximum) • Customized working temperature: -40ºC~125ºC • Signal Output: 4~20mA, 0/5~10V • Power supply: 10/11~30Vdc, 6~24Vdc, 10/20~36Vac • OEM: Available |
Wiring diagrams
Electric connect | |||
Cable | two wires | three wires | Hirschmann |
Red | power supply | power supply | 1 |
Blue/Green | output | output | 2 |
Black | shield | GND | 3 |
Yellow | - | shield | GND |
Signal output | |||
Two wires | 4~20mA | ||
Three wires | 0~5V, 0~10V (dc) | ||
Electric connection | |||
Cable | two wire | three wire | GX16-7 |
Red | power supply | power supply | 1 |
Blue/green | output | output | 2 |
Black | shield | GND | 3 |
Yellow | - | shield | 4 |
Signal output | |||
Two wires | 4~20mA | ||
Three wires | 0~5V, 0~10V (dc) |
Wiring diagrams
Standard range
Range | Overload | Output/F.S (mV) | Typical value(mV) | Pressure type |
0~10KPa | 300% | 35~60 | 45 | G |
0~20KPa | 300% | 70~110 | 90 | G/A |
0~35KPa | 300% | 55~80 | 70 | G/A/D |
0~70KPa | 300% | 55~80 | 60 | G/A/D |
0~100KPa | 300% | 60~85 | 75 | G/A/D |
0~200KPa | 300% | 60~85 | 75 | G/A/D |
0~400KPa | 300% | 60~80 | 70 | G/A/D |
0~600KPa | 200% | 90~120 | 100 | G/A/D |
0~1.0MPa | 200% | 125~185 | 150 | G/A/D |
0~1.6MPa | 200% | 80~120 | 100 | G/A/D |
0~2.0MPa | 200% | 50~70 | 60 | G/A/D |
0~3.5MPa | 200% | 100~120 | 110 | G/A/D |
0~7.0MPa | 200% | 120~150 | 135 | G/A |
0~10MPa | 200% | 180~230 | 200 | G/A |
0~25MPa | 150% | 140~170 | 150 | S |
0~40MPa | 150% | 230~280 | 250 | S |
0~60MPa | 150% | 100~160 | 130 | S |
0~100MPa | 150% | 100~150 | 120 | S |
Model selections