Hot Search: hoverboard  jetour  stainless  crankshaft  Rubber  ceiling  195/70r15c  headlight  tractor  TBR 

with Platinum Resistance to Accomplish Simultaneous Measurement of Temperature and Pressure Sensor CE, Gas Pressure Sensor, Air Pressure Sesnor

Supplier Nanjing Wotian Technology Co., Ltd.
Price $12.00 / Pieces
Availability In Stock
Mini Order:
+-
Subtotal: $120

Purchase details

Payments:

Tax:

Tax Included 

Returns&Refunds:

Eligible for refunds within 30 days of receiving products. returns and refunds 

 
Model NO.
PC20
Temperaurte Sensor
PT100 PT1000
Zero Output
±2mv
Excitation
1.5mA, 10V
Electrical Connection
Gold-Plated Kovar Pin or Silicon Soft Wire
Operating Temp.
-40ºC~120ºC
Measured Medium
All The Liquids and Gases Compatible with 316L.
Oil Filling
Silicon Oil
Sealing Ring
NBR or Fluorine Rubber
Transport Package
Standard Export Packing with Carton
Specification
Diameter: 19mm
Trademark
WTsensor
Origin
China
Type:
Piezoresistive Pressure Sensor
For:
Capacitive Pressure Transmitter
Material:
Stainless Steel
Certification:
RoHS
Pressure Range:
-100kpa...0~10kpa...100MPa
Pressure Reference:
Gauge, Absolute, Sealed Gauge
Product overview
PC20 temperature and pressure integrated sensor is based on PC10 and mounted with built-in platinum resistance to accomplish simultaneous measurement of pressure and temperature. The temperature measurement can meet the need for high-precision temperature compensation of the product.

Features

With constant current and constant voltage excitation options
Imported highly reliable pressure die
Wide temperature compensation
Normalized output available
Compensation board filled with glue for protection against moisture
Φ19mm standard OEM
All 316L material
High performance, all solid, high reliability
18 months warranty period
with Platinum Resistance to Accomplish Simultaneous Measurement of Temperature and Pressure Sensor CE
Applications
Process control systems
Pressure calibration instruments
Refrigeration equipment and HVAC control
Hydraulic systems and valves
Level measurement
Biomedical instruments
Ships and navigation
Aircraft and avionics systems
Weaponry

Equivalent circuitwith Platinum Resistance to Accomplish Simultaneous Measurement of Temperature and Pressure Sensor CE
Electrical performance parameters
 
Pressure range-100kPa~0~10kPa…100MPa
Pressure referenceGauge pressure, Absolute pressure, Sealed gauge pressure
Excitation1.5mA recommended for constant current
10V recommended for constant voltage
Input impedanceConstant current: 2kΩ~5kΩ
Constant voltage: 3kΩ~18kΩ
Electrical connectionGold-plated KOVAR pin or silicon soft wire
Compensation temp.Constant current: 0ºC~60ºC(≤70kPa), -10ºC~70ºC(other ranges);
Constant voltage: -20ºC~85ºC
Operating temp.-40ºC~120ºC
Storage temp.-40ºC~120ºC
Insulation resistance≥200MΩ/250VDC 
Response time≤1ms (up to 90%FS)
Measured mediumAll the liquids and gases compatible with 316L.
Mechanical vibration20g (20~5000Hz)
Shock100g (10ms)
Service life10×106 (cycles)
Structural performance parameters
 
Diaphragm material316L
Housing material316L
Oil fillingSilicon oil
Sealing ringNBR or fluorine rubber
 
Basic parameters
 
ItemConditionMinNominalMaxUnitNote
Nonlinearity -0.3±0.20.3%FSNote(1)
Hysteresis -0.05±0.030.05%FS 
Repeatability -0.05±0.030.05%FS 
Zero output -2±12mV 
Full scale span output1.5mA, 10kPa
1.5mA, other ranges
10V, 10kPa
10V, other ranges
30
60
60
98

90

100

150

102
mV 
Zero temp. coefficient10kPa
other ranges
-2
-1.5
±1.5
±0.75
2
1.5
%FSNote(2)
Span temp. coefficient -1.5±0.751.5%FSNote(2)
Thermal hysteresis -0.075±0.050.075%FSNote(3)
Long term stability -0.3±0.20.3%FS/Year 
Note:
(1) Calculate according to BFSL least square method.
(2) In the compensation temperature range, refer to 30ºC for 0ºC~60ºC and -10ºC~70ºC, and 32.5ºC, for -20ºC~85ºC.
(3) After passing high and low temperature, return to the reference temperature.
 
Structure and dimensions
 

with Platinum Resistance to Accomplish Simultaneous Measurement of Temperature and Pressure Sensor CE
 
Pressure range selection
 
CodePressure referencePressure rangeOverpressureBurst pressureO-ring
10kG0~10kPa300%FS600%FSNBR
20kG0~20kPa300%FS600%FSNBR
35kG, A0~35kPa300%FS600%FSNBR
70kG0~70kPa300%FS600%FSNBR
100kG, A0~100kPa200%FS500%FSNBR
160kG, A0~160kPa200%FS500%FSNBR
250kG, A0~250kPa200%FS500%FSNBR
400kG, A0~400kPa200%FS500%FSNBR
600kG, A0~600kPa200%FS500%FSNBR
1MG, A0~1MPa200%FS500%FSNBR
1.6MG, A, S0~1.6MPa200%FS500%FSNBR
2.5MG, A, S0~2.5MPa200%FS500%FSNBR
4MS0~4MPa200%FS400%FSNBR
6MS0~6MPa200%FS400%FSFluorine rubber
10MS0~10MPa200%FS400%FSFluorine rubber
16MS0~16MPa200%FS400%FSFluorine rubber
25MS0~25MPa150%FS400%FSFluorine rubber
40MS0~40MPa150%FS300%FSFluorine rubber
60MS0~60MPa150%FS300%FSFluorine rubber
100MS0~100MPa150%FS300%FSFluorine rubber
N1kOmitted-100~0kPa300kPa600kPaNBR
N2kOmitted0~-100kPa300kPa600kPaNBR
N3kOmitted±100kPa300kPa600kPaNBR
N4kOmitted-100~160kPa480kPa900kPaNBR
N5kOmitted-100~250kPa750kPa1.25MPaNBR
N6kOmitted-100~400kPa800kPa2MPaNBR
N7kOmitted-100~600kPa1.2MPa3MPaNBR
N8MOmitted-0.1~1MPa2MPa5MPaNBR
N9MOmitted-0.1~1.6MPa3MPa9MPaNBR
N10MOmitted-0.1~2.5MPa5MPa12.5MPaNBR
Note: G: Gauge pressure, A: Absolute pressure, S: Sealed gauge pressure
 
How to order
 

with Platinum Resistance to Accomplish Simultaneous Measurement of Temperature and Pressure Sensor CE

Example: PC20-10kG4wI1Z1
Refer to PC20 pressure sensor, with pressure range 10kPa, gauge pressure, 4 wire, 1.5mA excitation, temperature measuring element Pt100.

Ordering tips:
1 Pressure range can be selected higher or lower than actual conditions but should be within ±30%FS.
2 Pressure reference consists of gauge pressure, absolute pressure and sealed gauge pressure.
  • Gauge pressure is based on the current atmospheric pressure. Generally, it refers to the measurement of pressure which is greater than the current atmospheric pressure. Negative pressure is a special case of gauge pressure. It refers that there is such working condition that the pressure of work site is lower than the current atmospheric pressure.
  • Absolute pressure is based on vacuum.
  • As for sealed gauge pressure, PC10 uses absolute pressure die for gauge pressure product based on the atmospheric pressure of production site. For pressure range above 6MPa, gauge pressure cannot be selected, but only sealed gauge pressure.
3 Confirm the maximum overload of the applied system, which should be less than the overload protection limit of the sensor, otherwise it will affect the product life or even damage the product.
4 The commonly used compensation of the product is 1.5mA constant current compensation. Suggest to select the option with priority.
5 The material and process for manufacturing negative pressure sensors are different from those of positive pressure sensors. So gauge pressure sensors cannot be used as substitute of negative pressure sensors.
6 For special requirements on performance parameters and functions of the product, please contact us.
with Platinum Resistance to Accomplish Simultaneous Measurement of Temperature and Pressure Sensor CE
with Platinum Resistance to Accomplish Simultaneous Measurement of Temperature and Pressure Sensor CE
with Platinum Resistance to Accomplish Simultaneous Measurement of Temperature and Pressure Sensor CE
with Platinum Resistance to Accomplish Simultaneous Measurement of Temperature and Pressure Sensor CE
with Platinum Resistance to Accomplish Simultaneous Measurement of Temperature and Pressure Sensor CE
Certifications:
with Platinum Resistance to Accomplish Simultaneous Measurement of Temperature and Pressure Sensor CE
 
Send Message
Message Type
*Content
*Your Name  
*Tel
*Email
* Captcha  
You May Like
Related Search: Gas Pressure Sensor Air Pressure Sesnor Vehicle Parts & Accessories Motor Vehicle Parts Motor Vehicle Sensors Pressure Sensor