Model NO.
MP-2
Type
Gas Sensor
Conductivity Type
Non-conductivity Type
Output Signal Type
Analog Type
Production Process
Ceramics
Material
Metal
IP Rating
IP20
Sensitivity
High
Certification
CE
Customized
Customized
Sensor Type
Semiconductor Flat Surfaced
Detection Gas
Smoke
Detection Range
200-10000ppm
Trademark
DESON
Transport Package
Cartons
Specification
200-10000ppm
Origin
China
MP-2 model with advanced planar construction is comprised of heater and metal oxide semiconductor material of subminiature Al2O3 ceramic plate, fetch out electrode down-lead, encapsulation in metal base and cap. When the target gas exists , the sensor's conductivity is more higher along with the gas concentration rising. Please use simple electrocircuit, convert change of conductivity to correspond output signal of gas concentration.
Features:
* Good sensitivity to LPG, smoke in wide range
* Small size
* Long lifespan
* Low cost
*Simple circuit
Application Domestic smoke leakage alarm, industrial smoke gas alarm and portable smoke detector
Features:
* Good sensitivity to LPG, smoke in wide range
* Small size
* Long lifespan
* Low cost
*Simple circuit
Application Domestic smoke leakage alarm, industrial smoke gas alarm and portable smoke detector
Technical indicators
| Product number | MP-2 | ||
| product type | Flat Surfaced Semiconductor gas sensor | ||
| Standard package | Bakelite , plastic | ||
| Detection of gasOzone | Smoke | ||
| Detection of concentration | 200-10000ppm | ||
| Standard circuit conditions | Circuit voltage | VC | ≤24V DC |
| Heating voltage | VH | 5.0V ± 0.1V ACorDC | |
| Load Resistance | RL | Adjustable | |
| Characteristics of Gas Sensors under Standard Test Conditions | Heating resistance | RH | 29 ± 3Ω (room temperature) |
| Heating power consumption | PH | ≤900mW | |
| The output voltage | Vs | 2.5-4.0V (in 125ppm) | |
| Sensitivity | S | Rs (in air) / Rs (125 ppm ) ≥5 | |
| Concentration slope | Α | ≤0.6 (R300ppm/ R125ppmalcohol) | |
| Standard test conditions | temperature humidity | 20 ° C ± 2 ° C; 55% ± 5% RH | |
| Standard test circuit | VC: 5.0V ± 0.1V VH: 5.0V ± 0.1V | ||
| Warm up time | Not less than 48 hours | ||
Note: Product parameters are subject to change without notice