Model NO.
BWR-01A
Type
Gas Detector
Conductivity Type
Gas Sensor Probe
Output Signal Type
Digital Type
Production Process
Catalytic Gas Sensor
Material
Plastic
Sensitivity
High
Certification
CE
Customized
Non-Customized
Working Voltage
AC100V~AC240V 50~60 Hz
Alarm Format
Audible & Visual Alarm, Remote Alarm (Work with Al
Alarm Level
First Level Alarm, 10%Lel
Color
White
Trademark
Ansee
Transport Package
Carton
Specification
115*72*46.5 mm
Origin
China
HS Code
85319010
Specification
Model Name | BWR-01A |
Working Voltage | AC100V~AC240V 50~60 HZ |
Temperature | 0ºC~50ºC |
Humidity | 10%~95% RH |
Alarm Level | First level alarm, 10%LEL |
Alarm Reset | Auto reset when the fuel gas is cleared |
Alarm Format | Audible & Visual alarm, remote alarm (work with alarm host) |
RF Distance | <=30M (open area); |
Radio Frequency | 915MHz/FSK |
Measurement | 115*72*46.5 mm |
Operation Instructions
1. Powered on,the yellow LED and Red LED will normal be on for 1 second. Then buzzer will give"di"
sound and Red LED starts to flash. The detector goes into preheating status for 3 to 5 minutes. After
that,the red LED will be normal on and the detector goes into standby status.
2. For product test: press test button, the red LED will flash fast and make "di- di- di ..." sound, also
it will send alarm signal to alarm host through RF .
3. Solenoid Valve Connection: the positive pole connects to SIG+ of detector, the negative pole
connects to SIG- of detector(optional).