Model NO.
O2/D-13
Type
Electrochemical Gas Sensor
Conductivity Type
Volume Control Type
Output Signal Type
Digital Type
Production Process
Integration
Material
PA, PPS, PTFE, Stainless Steel
IP Rating
IP20
Sensitivity
High
Certification
RoHS
Customized
Customized
Output
Ttl/4-20mA/RS485
Transmitter Board
Integrated/Seperated
Wire
Two or Three Wire
Detecting Range
Selectable
After Sale Service
Yes
Trademark
ITG
Transport Package
Factory Sealed
Specification
Max29.2*41.4
Origin
Germany
HS Code
9027100090
Galvanic gas sensor with an extra water repellent head space.
All characteristics are based on conditions at 25°C, 50% RH and 1013 hPa
Key Feature
Measurement Range | 0 to 100 Vol.% |
Expected Operating Life | ~ 750,000 Vol.% h |
Sensor Lifetime | <3 years @ ambient air |
Electrical Connector | 3-pin Molex® |
Initial Output Signal | 7.0-13.5 mV @ dry ambient air |
Response Time t90 | <5 s |
Drift | <1% volume O2/month @ air, averaged across 12 months |
Operating Temperature | 0 to 45ºC |
Pressure Range | 600 to 1750 hPa |
Recommended Load Resistor | ≥ 10 kOhm |
Linearity Error | <3 % @ 100 % O2, applied for 5 min |
Zero Offset Voltage | < 150 μV in 100% N2, applied for 5 min |
Influence of Humidity | - 0.03 % rel. O2 reading per % RH |
Temperature Compensation | NTC |
Interferences | none to He, H2 and CO |
Weight | approximately 24 g |
Material in Contact with Media | PA, PPS, PTFE, stainless steel |
Storage Condition
Temperature Range | recommended: 5 to 30 °C maximum: -20 to 50 °C |
Humidity | up to 100 % RH |
Shelf Life | < 6 months recommended |
Ambient Pressure | 600 to 1750 hPa |
Oxygen Module Parameters
Module type | GM-I2(3)-M/C/S-**-****/G/P/F/FL |
Detected gas | Toxic gas |
Detecting principle | Electrochemistry |
Sampling | Diffusing pump flange thread |
Responding time | 30s~40s(of the sensor) |
Module accuracy | ≤±3%FS(actual concentration, higher accuracy depends on specified sensors) |
Module repeatability | ≤±2% FS |
Module linear error | ≤±2% FS |
Module zero temperature drift | ≤±2% (FS/year) |
Module operating temperature | -40~80°C |
Module humidity | 0-95%RH(non-condensation) |
Sensor operating temperature | -20°C~50°C |
Sensor humidity | 0-90%RH(non-condensation) |
Signal output | TTL/4-20mA /RS485 (two or three wire) |
Transmitting distance | 1000 meters(RS485) |
Operating voltage | DC 12-36V |
Maximum power | ≤0.8W |
Size | 80*48mm |
Explosion proof | Intrinsic safe |
Connection cable | RVVP3 x 1.5mm² |
Oxygen Module Applications
Petroleum, petrochemical, metallurgy, chemical, electricity, telecom, gas, mining, pharmacy, municipal wastewater treatment, indoor environment, atmospheric environmental protection, transit equipment, transportation facilities, tunnel safety and underground parking, leak detection, safety and environmental control