Model NO.
AW-AGD2188
Certification
CE
Customized
Non-Customized
Wire
2 Wire
Temperature
0-55
Working Humidity
95%Rh, Non-Condensation
Working Current
DC24V
Color
White
Nature
Addressable
Weight
0.2kg
Design
OEM ODM
Install
Wall Amounted
Match
Addressable Fire Alarm Panel
Transport Package
Carton
Specification
CE ISO9001
Trademark
ASENWARE
Origin
Shenzhen
HS Code
8531100000
Production Capacity
10000/Year
Type:
Infrared Gas Sensor
Conductivity Type:
Surface Type
Output Signal Type:
Analog Type
Production Process:
Integration
Material:
Plastic
Sensitivity:
High
Addressable Fire Alarm System Gas Detector
AW-AGD2188 type measurement range of 0-100% LEL of point combustible gas detectors (hereinafter referred to as detector) screen printing a thick film with high quality metal oxide semiconductor sensor for detecting combustible gas leaks, apply security monitoring in homes, factories, hotels, apartments and other presence of flammable gases, can access the ASENWARE addressable fire alarm control system to achieve network connectivity.
Packaging & Shipping
Packaging Details:
1) PEE bag per unit
2) Outside Cartons
3)Strict & Standard Export Packing Procedures Adopted Exterior Corrugated Hardboard Carton Interior Blister Buffer Staff, Asenware fire pump control equipment.
Our company
Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with factory Shenzhen, China
We keep our best service for our customers, and have a rich experienced engineer team to design and install for overseas projects.
Product range
1. Addressable fire alarm system(FP100 series,2189,2100 series)
2. Conventional fire alarm system(2166 series)
3. FM200 gas fire suppression system
4. Emergency light system
5. Fire pump system
6. Fire hose and fire hose reel cabinet
Our Services
1.OEM / ODM services.
2.Professional technical team.
3.Offer Free technical support whenever you need
4.Two year warranty and technical maintenance
FAQ
Q1: Are you manufacturer?
A: (yes)
Q2: What is the lead time?
A: usually
Fire control: one week working day
bulk quality: three weeks working days
Emergency lights: two weeks working days
bulk quality: four weeks
FM200: two weeks working day
Fire pump: 25 days
Q3: How do you ship the goods and how long does it take arrive?
A: We usually ship by DHL, UPS, FedEx or by Air. 3-5 days after payment received.
Q4: Can I have a sample order?
A:Yes,we welcome sample order to test and check quality.
Q5: Do you offer OEM service?
A: Yes, we can design the things according to your request.
Item | Index Parameter |
Environment Temperature | 0ºC~+55ºC |
Working Humidity | ≤95%RH, Non-condensation |
Operating Voltage | DC24V, Operating Voltage Range: 12~28V |
Working Current | ≤ 35mA @DC24V (Standby), ≤ 40mA @DC24V Alarm) |
Linkage | Non-polarity analog 2 wire bus, current < 400uA |
Value of Detection Concentration | Natural gas 10%LEL(±30%) |
Response time | ≤30S, Self-recovery |
service life | >5 Year (In clean air) |
Electricity (or reset) | The electric (or reset) indicator on the detector quickly double flash, after light according to the order of the green, red, yellow flashing light, accompanied by a buzzer hint sound. |
Indicator light | Preheat condition, the green light shining fast (about 2 times per second); Normal monitoring status, the green light is about once every 12 seconds flicker when there is no bus signal access (about once per minute flashing); Alarm, the red indicator light flash (about 2 times per second); The sensor failure, the yellow indicator light about once every 3 seconds flicker. |
Buzzer | When alarm, buzzer about chirping 2 per second;To failure, buzzer about sing once every 3 seconds. |
Self-inspection Button | Press the self-check button, indicator light cycle shiny (order of green, red, yellow), accompanied by a buzzer sound prompt. |
Unit Dimensions | φ104mm×48 mm |
Shell material | ABS(Antiflaming V0) |
AW-AGD2188 type measurement range of 0-100% LEL of point combustible gas detectors (hereinafter referred to as detector) screen printing a thick film with high quality metal oxide semiconductor sensor for detecting combustible gas leaks, apply security monitoring in homes, factories, hotels, apartments and other presence of flammable gases, can access the ASENWARE addressable fire alarm control system to achieve network connectivity.
Packaging & Shipping
Packaging Details:
1) PEE bag per unit
2) Outside Cartons
3)Strict & Standard Export Packing Procedures Adopted Exterior Corrugated Hardboard Carton Interior Blister Buffer Staff, Asenware fire pump control equipment.
Our company
Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with factory Shenzhen, China
We keep our best service for our customers, and have a rich experienced engineer team to design and install for overseas projects.
Product range
1. Addressable fire alarm system(FP100 series,2189,2100 series)
2. Conventional fire alarm system(2166 series)
3. FM200 gas fire suppression system
4. Emergency light system
5. Fire pump system
6. Fire hose and fire hose reel cabinet
Our Services
1.OEM / ODM services.
2.Professional technical team.
3.Offer Free technical support whenever you need
4.Two year warranty and technical maintenance
FAQ
Q1: Are you manufacturer?
A: (yes)
Q2: What is the lead time?
A: usually
Fire control: one week working day
bulk quality: three weeks working days
Emergency lights: two weeks working days
bulk quality: four weeks
FM200: two weeks working day
Fire pump: 25 days
Q3: How do you ship the goods and how long does it take arrive?
A: We usually ship by DHL, UPS, FedEx or by Air. 3-5 days after payment received.
Q4: Can I have a sample order?
A:Yes,we welcome sample order to test and check quality.
Q5: Do you offer OEM service?
A: Yes, we can design the things according to your request.
Send Message