Model NO.
RK210
Type
SemiConductor Gas Sensor
Output Signal Type
Digital Type
Material
ABS
IP Rating
IP65
Sensitivity
High
Certification
CE FCC RoHS
Customized
Customized
Power Supply
DC 10-30V
Display Screen
2 Inch Color Screen
Maximum Power Consumption
2.5W
Signal Output
RS485 Output
Moisture Resistance Level
Ipx4
Trademark
Rainbow
Transport Package
Standard
Specification
100*85*26mm
Origin
China
HS Code
9026801000
Multi in one air quality monitoring transmitter
1. product description
RK-210 is an air environment comprehensive index monitor independently developed by our company. It is used to detect PM2.5, PM10, temperature, humidity, pressure, light, ultraviolet light, TVOC, O2, carbon dioxide (CO2) and carbon monoxide in the air environment. (CO), formaldehyde (CH2O) micro pressure difference and other parameters. The function is very powerful, basically covering various indicators reflecting air quality.The transmitter adopts imported original sensor and calculation chip, with high precision, high resolution and good stability. It is widely used in building HVAC, building energy saving, smart home, schools, hospitals, airport stations and other places.2. Functions and features
1.Integrate a variety of measurement elements into one,The function is very powerful.
2.The temperature and humidity measurement unit is imported from Switzerland, and the measurement is accurate.
2.The temperature and humidity measurement unit is imported from Switzerland, and the measurement is accurate.
3.PM2.5 and PM10 are collected at the same time, range: 0-1000ug/m3, resolution 1ug/m3, unique dual-frequency data collection and automatic calibration technology, consistency can reach ±10%.
4.The gas unit adopts electrochemical and catalytic combustion sensors, which have excellent sensitivity and repeatability.
5.The TVOC measurement unit adopts imported high-sensitivity gas detection probes, with mature technology and high-performance signal acquisition circuits, with stable signals and high accuracy.
6.Wide range 0-120Kpa air pressure range, can be applied to various altitudes.
7.Using dedicated 485 circuit, stable communication, 10~30V wide voltage range power supply.
3. Technical indicators
DC power supply (default) | DC 10-30V AC220VAC |
Display screen | 2 inch color screen |
Maximum power consumption | 2.5W (24V DC power supply) |
Detection parameters | Temperature, humidity, PM2.5, PM10, air pressure, light, TVOC, CO2, formaldehyde, O3, CO, CH4, O2, SO2, NO2, H2, H2S, NH3 |
working environment | Temperature -10ºC-55ºC; humidity 0~95%RH non-condensing |
Signal output | RS485 output (standard Modbus-RTU protocol)) |
product material | ABS |
Installation method | Wall hanging, ceiling |
Protection level | IP65 |
Moisture resistance level | IPX4 |
Detection parameters | Range | Resolution | Precision | Preheat time |
PM2.5 | 0~1000ug/m3 | 1ug/m3 | ±10% | ≤2min |
PM10 | 0~1000ug/m3 | |||
temperature | -40ºC~+120ºC | 0.1ºC | ±0.5ºC(25ºC) | |
humidity | 0%RH-100%RH | 0.1%RH | ±3%RH(60%RH,25ºC) | |
atmospheric pressure | 0~120Kpa | 0.1Kpa | ±0.15Kpa@25ºC75Kpa | |
TVOC | 0~60000ppb | 1ppb | ±8%FS±125ppb | |
carbon dioxide | 0~5000ppm | 1ppm | ±(40ppm+ 3%F·S) | 2min (available), 10min (maximum accuracy) |
formaldehyde | 0~5ppm | 0.01ppm | ±5%FS | ≥5 minutes |
ozone | 0~5ppm | 0.01ppm | ±6%FS | ≥5 minutes |
O2 | 0~25%Vol | 0.1%Vol | ±3%FS | ≥5 minutes |
H2S | 0~100ppm | 1ppm | ±3%FS | ≥5 minutes |
CH4 | 0~100%LEL | 1%LEL | ±5%FS | ≥5 minutes |
CO | 0~1000ppm | 1ppm | ±5%FS | ≥5 minutes |
NO2 | 0~20ppm | 0.1ppm | ±5%FS | ≥5 minutes |
SO2 | 0~20ppm | 0.1ppm | ±3%FS | ≥5 minutes |
H2 | 0~1000ppm | 1ppm | ±3%FS | ≥5 minutes |
NH3 | 0~100ppm | 1ppm | ±3%FS | ≥5 minutes |
All the above specification parameters are measured under the following environmental conditions, except those that have been specifically explained: temperature 20°C, relative humidity 50%RH, 1 atmosphere, and the maximum concentration of the measured gas does not exceed the range of the sensor. Electrochemical probe can only integrate 1 type of probe.