Model NO.
EFM002
Type
Flow Meter
Measuring Medium
Liquid
Material
Metal
Accuracy Grade
±0.5% RS.
IP Rating
Integrated Type IP65, Remote Type IP68
Certification
RoHS
Customized
Customized
Output
Analog Sensor
Usage
Liquid Level Sensor
Theory
Faraday′s Law of Electromagnetic Induction
Trademark
ouke
Transport Package
Carton
Specification
CE
Origin
China
HS Code
9026100000
LCD Dislay Electromagnetic flow meter is a kind of inductional instrument designed by Faradays' law of electromagnetic induction to measure flow of conductive media in the tube. It adopts the technology of insertion of single chip to realise digital excitation and employs CAN local fieldbus. Electromagnetic flow meter can realize local indication and output electrical current signal of 4-20mA which can be used to record, adjust and control. Electromagnetic flow meters are widely used in industrial sectors such as chemical industry, environmental protection, metallurgy, pharmaceutical, paper making, water supply and removal etc.
This Electromagnetic Flow Meter has no mechanical inertia, quick response and good stability, application in automatic examination, and regulation and controlling. It is used to measure flow of any kind of conductive liquid and our product range also includes process control instruments and electronic process control instruments. This range of Flow Meter operates data for safe and firm protection of memory. These are used for measuring accuracy is uninfluenced by the physical parameters such as type, temperature, viscosity, density and pressure.
Features
Accuracy of measurement is high ± 0.5% (can also be ± 0.2%), security is also high
Range of flow is wide, the measuring range scale is1500: 1
Inexpensive flowmeter system can adopt in the measurement of water and waste water
Design of blast resistant construction is used in chemical industry
Design of sanitation is used in food and medical industry
Due to knock-down electrode structure, it can be maintained on line and the electrode can be charged
Automatic detection of suction pipe can eliminate wrong measurement
HART-agreement or profibus communication bus
Applications
It is used to measure the volumetric flow of the conductive liquid and slurry in the closed conduits in such industries as water & wastewater, chemical, petroleum, metallurgical, power, pharmaceutical, food, beverage, pulp & paper, etc.
Technical parameters
Item | The Specifications of electromagnetic flow meter | ||||||||
Measuring fluid | conductive fluid | ||||||||
Normal diameter(mm) | DN10-DN1000 | ||||||||
Electrode materials | Mo2Ti HC HB Pt Ta Ti | ||||||||
Lining Material | PTFE, PFA (resistance to negative pressure), chloroprene rubber, polyurethane, hard rubber (optional conductive ground rubber ≥ DN125) | ||||||||
Electrode Type | Standard type 316L, scraper-type (DN ≥ 50) | ||||||||
Dielectric conductivity | > 5μs/cm (water> 20μs/cm) | ||||||||
Accuracy grade | ±0.5% RS. | ||||||||
Repeatability | ±0.1% | ||||||||
Flow Range | 0-10m/s | ||||||||
Maximum temperature of medium | A size ≤ 90 , min size ≤ 180 (rubber ≤ 65 ) | ||||||||
Measuring temperature | -20 - 140 °C | ||||||||
Working pressure | 1.0Mpa-4.0Mpa, the special supplier overpressure | ||||||||
Protection Level | IP65, IP68 (optional) | ||||||||
Output | 4-20mA current output ,0-1kHz frequency output, pulse output per unit volume | ||||||||
Power | 85-265V, 45-450Hz | ||||||||
Standard | Q/SMAU2-2006 | ||||||||
Auxiliary converter | BF900C/F | ||||||||
Flange | National standard GB9115, ANSI, JIS | ||||||||
Installation Type | Split, integrated |