Model NO.
ANEVT800-600DA
After-sales Service
Yes
Certification
ISO, ISO
Output Type
Single
Warranty
1 Year
Output Power
>500W
Modulation System
PWM
Brand
Ainuo
After-Sales Service
Provide After-Sales Service
Manufacturer
Yes
Grid Feedback Function
Yes, It Can Be Power Source or Load
Output Precision
Output Voltage/Current Precision 0.1%F.S
Working Mode
Cc/CV/Cp
Protection
Otp/Ovp/OPP/SCP/Rvp/Ssp/Oop/Hwp/Swp
Communication Port
Can/RS232/RS485
Lock
Yes, Auto-Lock If No Operation After 5 Mins
Applications
Electric Vehicles, Fuel Cells, Motors, Charging Pi
Trademark
Ainuo
Transport Package
Wooden Case
Specification
1000*2000*1000
Origin
Jinan
Product Description
ANEVT series dual-channel bidirectional DC power supply adopts high-frequency PWM rectification and bidirectional DCDC conversion, FPGA digital control, seamless switching between forward and reverse, automatic bidirectional operation, energy feedback to the grid at full power; advanced digital control, ultra-high control accuracy, fast response; two channels independently configured and not affect each other, which can be used in parallel to expand the DC output capacity and reduce investment by customer; abundant programming and testing functions, suitable for a variety of applications with different upper computer software.
Detailed Photos
Independent channel configuration: each channel is independently programmed, voltage, current and power parameters are set independently, and the operating parameters in programming mode are set independently. The channels are independent of each other and do not affect each other.
Parallel channels: The two channels do not affect each other, and can be used in parallel.
Grid feedback: both power supply and load characteristics, achieving the function of load for automatic energy feedback to the grid in addition to high-power DC power supply performance; energy saving, green and environment protection.
High-precision output: accuracy of output voltage: ±0.05% F.S.
Fast dynamic response: output voltage response time for 10%-90% sudden applied load and 90%-10% sudden shedding load: ≤5ms; +90%~-90% forward/reverse switching time: ≤10ms.
Mainstream high-frequency PWM rectification control, power factor ≥0.99, THD and injected harmonic current meet the requirements of GB/T14549-93, high-quality energy feedback to the grid.
Advanced IGBT parallel technology, efficient and reliable.
CC, CV, CP modes.
Multi protection: input over-voltage/under-voltage, lack phase, output over voltage, IGBT overheat, IGBT over current, over temperature protection, short circuit current-limiting protection.
Built-in EMI filter to filter the interference signal caused by the high-frequency switching process.
Communication and remote control: standard CAN, RS232/RS485 port and remote control software of the upper computer.
Programmable slow-rise output.
Applications:Testing of electric vehicle motors and controllers
Testing of electric vehicle transmission system and powertrain system
Testing of special electric vehicle motors, controllers, electric vehicle transmission systems, and powertrain systems
Testing of fuel cell
Testing of new energy motor system
Testing of ship electric drive, electric drive system
Testing of charger and charging pile
Testing of battery pack charge/discharge
Testing of capacitor and super capacitor charge/discharge
Testing of energy storage system converter
Testing of UPS and EPS system
Testing of hybrid
Simulated battery to replace real battery-powered test applications
Power supply for high-power DC test
Product Parameters
Voltage level | Product model | Rated current per channel (A) | Peak current per channel (A) | Rated power per channel (kW) | Peak power per channel (kW) | Peak time (S) |
24-800V | ANEVT800-600DA | 600 | 780 | 200 | 260 | 60 |
Description |
|
General parameters of dual channel ANEVT(F) series | ||
Input parameters | Input Power | 4-phase 3-wire +PE, line voltage 380V±57V, 50/60Hz±5Hz |
Isolation function | Built-in isolation transformer | |
Input power factor | 0.99 (rated conditions) | |
Input current distortion | 5% (rated conditions) | |
Output parameters | Voltage accuracy | 0.05% F.S, resolution: 0.1V |
Current accuracy | 0.1% F.S, resolution: 0.1A | |
Power accuracy | 1% F.S, resolution: 10W | |
Power supply effect | Source effect: 0.1% F.S, load effect: 0.1% F.S | |
Ripple (Vpp) | 0.2%F.S | |
Transient recovery time | 5 ms | |
Current rise time | 10ms (10%~90%, resistive load, test condition: power output, load test on) | |
Protection | IGBT overheat, IGBT overcurrent, transformer overheat, input overvoltage, input undervoltage, output overvoltage, output overcurrent, lack phase protection | |
Three-phase line voltage | 323~437V (allowed grid voltage) | |
Feedback parameters | Frequency | 45~65 (allowed grid frequency) |
Power factor | 0.99 (rated conditions) | |
Total harmonic content | 5% (rated conditions) | |
Switching time | 10ms (forward maximum current to reverse maximum current) | |
Feedback function | Energy feedback at full power | |
Function | Wave editing | Control of voltage/current slope, ladder, cycle control, jump control |
E-stop | E-stop button | |
Battery simulation | With battery simulation function | |
Soft start | Pre-charge | |
Communication port | Standard Can port/RS232 port, optional RS485/LAN. | |
Output contactor | Available and controllable | |
Discharge protection | Discharge Unit protection unit | |
Fan speed control | Fan temperature control and speed regulation | |
Switch input interface | 3 channel | |
Switch output interface | One for each channel, indicating alarm status of the channel | |
Working environment | Temp./humidity | 0~40ºC, 10~90%RH (no condensation) |
Altitude | ≤2000m |
Company Profile