• Conductor: Class 1 Solid Copper Class 2 stranded Copper or Aluminum
• PVC/XLPE insulation
• Filler: Polypropylene lament with lapped binding tape
• PVC inner sheath
• Core-covering: Binding tape
• PVC outer sheath
PVC/XLPE Insulated Power Cable meets or exceeds the following standards: IEC 60502, BS, DIN, ASTM, GB12706-2008 standards.
XLPE power cable for static outdoor application (with protection against direct UV-irradiation), in ground, in water, within facilities, in cable canals, in concrete, in conditions where heavier mechanical loads and specially tensile strains, are not expected. Used in electric power plants, transformer stations, industrial plants, metropolitan networks and in other electric plants, same as for connection of signalling devices in industry, traffic and similar.
Rated Voltage, No. of Core, and Range of Sectional Area
Rated voltage (kV) Sectional area (mm2) No. of core | 1st class | 0.6/1 | 1.8/3 | 3.6/6 | 6/10 | 8.7/15 | 12/20 | 18/30 | 21/35 |
2nd class | 1/1 | 3/3 | 6/6 | 8.7/10 | 12/15 | 18/20 | - | 26/35 | |
1 Core | 1.5-800 | 25-800 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 | |
2 Core | 1.5-185 | 25-185 | |||||||
3 Core | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | |
4 Core | 2.5-400 | 25-400 | |||||||
5 Core | 2.5-400 | 25-400 |
2). DC resistance: conductor resistance of the finished cable at 20ºC per kilometer is not more than the following values.
Nominal section area (mm2) | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 | 240 | 300 | 400 | 500 | 630 | 800 |
Copper core | 12.1 | 7.41 | 4.61 | 3.08 | 1.83 | 1.15 | 0.727 | 0.524 | 0.387 | 0.268 | 0.193 | 0.153 | 0.124 | 0.099 | 0.0754 | 0.0601 | 0.047 | 0.0366 | 0.0283 | 0.0221 |
Aluminum core | 18.1 | 12.1 | 7.41 | 4.61 | 3.08 | 1.91 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 | 0.125 | 0.1 | 0.778 | 0.0605 | 0.0469 | 0.0367 |
3). Voltage Test and Partial Discharge Test
Rated voltage Uo (kV) Item | 0.6/1 | 1.8/3 | 3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/20 18/30 | 21/35 | 26/35 | ||
Voltage | Test voltage | 3.5 | 6.5 | 12.5 | 21 | 30.5 | 42 | 63 | 73.5 | 91 | |
Test time | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | ||
Partial discharge test | Test voltage | - | - | 6.2 | 10.4 | 15.1 | 20.8 | 31.1 | 36.3 | 45 | |
Discharge capacity | - | - | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Technical Parameters:
No.of cores x Nominal section area | Nominal Construction of conductor | Nominal Insulation thickness | Nominal Sheath thickness | Nominal Overall diameter | Nominal Cable weight | Max.Resistance of conductor at 20ºC |
No.X mm² | No.X mm | mm | mm | mm | kg/km | <=(Ω/km) |
Four core XPLE Power Cables CU/XLPE/PVC( AL/XLPE/PVC ) | ||||||
4x1.5 | 2x 1.38 | 0,7 | 1,8 | 12.1 | 150 | 12,10 |
4x2.5 | 7 x 0,67 | 0,7 | 1,8 | 13.2 | 200 | 7,41 |
4x4.0 | 7 x 0,85 | 0,7 | 1,8 | 14.9 | 275 | 4,61 |
4x6.0 | 7 x 1,04 | 0,7 | 1,8 | 16.1 | 370 | 3,08 |
4x10 | 7 x 1,35 | 0,7 | 1,8 | 18.6 | 560 | 1,83 |
4x16 | 7 x 1,70 | 0,7 | 1,8 | 20.2 | 795 | 1,150 |
4x25 | 7 x 2,14 | 0,9 | 1,8 | 21.8 | 1130 | 0,727 |
4x35 | 7 x 2,52 | 0,9 | 1,8 | 24.1 | 1515 | 0,524 |
4x50 | 19 x 1,78 | 1,0 | 1,9 | 27.5 | 2010 | 0,387 |
4x70 | 19 x 2,14 | 1,1 | 2,0 | 31.7 | 2860 | 0,268 |
4x95 | 19 x 2,52 | 1,1 | 2,1 | 35.4 | 3870 | 0,193 |
4x120 | 37 x 2,03 | 1,2 | 2,3 | 39.2 | 4850 | 0,153 |
4x150 | 37 x 2,25 | 1,4 | 2,4 | 43.8 | 5980 | 0,124 |
4x185 | 37 x 2,52 | 1,6 | 2,6 | 48.7 | 7480 | 0,0991 |
4x240 | 61 x 2,25 | 1,7 | 2,8 | 54.4 | 9735 | 0,0754 |
4x300 | 61 x 2,52 | 1,8 | 3,0 | 59.9 | 12120 | 0,0601 |
1.Our Shipyard:Ningbo Zhenhe shipyard, and now Taihang is the branch representative of our yard.
2.Our founding team has experience of more than 15 years in ship building and ship repair with our own engineer and designer.
3.Equipment quality guarantee: Based on shipyard feedback, we built up manufacturer file to ensure the good quality of the products. Also we can send our engineers to help our clients to install and test these exported equipment.
4.We are a second hand ship broker to help you find the satisfied used different kind vessels.
5.We are able to provide the CKD kits and one-stop service based on our laser-cutting machine and purchase ability
6.We have a very professional design and technical team to work out perfect plan for our clients and help to slove out any matters with pre-sale and after-sale.
7.Customer Distribution: Tananzia, Rwanda, India(Mumbai and Kalkatta), Suva, Portugal, Russia, Nertherland, Iceland, Denmark, Malaysia, Mexico......