WTB26I-24161120A00
Thru-Beam Sensor
Switching Type
IP67
CE
Non-Customized
AIMIQU
Carton
Germany
8481100090
Product Description
New and Original Sick COMPACT PHOTOELECTRIC SENSORS WTB26I-24161120A00
Detailed technical data
Features
Safety-related parameters
Communication interface
Electrical data
1) Limit values.
2) Signal transit time with resistive load in switching mode.
3) With light/dark ratio 1:1.
4) This switching output must not be connected to another output.
Mechanical data
Ambient data
1) Replaces IP69K with ISO 20653: 2013-03.
1) Replaces IP69K with ISO 20653: 2013-03.
Smart Task
1) Use of Smart Task functions without IO-Link communication (SIO mode).
2) Use of Smart Task functions with IO-Link communication function.
Diagnosis






Detailed technical data
Features
| Functional principle | Photoelectric proximity sensor |
| Functional principle detail | Background suppression |
| Sensing range Sensing range min. Sensing range max. Adjustable switching threshold for background suppression Reference object Minimum distance between set sensing range and background (black 6% / white 90%) Recommended sensing range for the best per- formance | 30 mm 2,000 mm 180 mm ... 2,000 mm Object with 90% remission factor (complies with standard white according to DIN 5033) 85 mm, at a distance of 800 mm 200 mm ... 800 mm |
| Emitted beam Light source Type of light Shape of light spot Light spot size (distance) Maximum dispersion of the emitted beam around the standardized transmission axis (squint angle) | LED Infrared light Point-shaped Ø 14 mm (1,000 mm) < +/- 1.0° (at Ta = +23 °C) |
| Key LED figures Normative reference | EN 62471:2008-09 | IEC 62471:2006, modified |
| LED risk group marking | Free group |
| Wave length | 850 nm |
| Average service life | 100,000 hat Ta = +25 °C |
| Adjustment Teach-Turn adjustment IO-Link | BluePilot: For setting the sensing range For configuring the sensor parameters and Smart Task functions |
| Indication | |
| LED blue | BluePilot: sensing range indicator |
| LED green | Operating indicator Static on: power on Flashing: IO-Link mode |
| LED yellow | Status of received light beam Static on: object present Static off: object not present |
| MTTFD | 626 years |
| DCavg | 0% |
| TM (mission time) | 20 years (EN ISO 13849, rate of use: 60 %) |
| IO-Link | Data transmission rate Cycle time Process data length Process data structure VendorID DeviceID HEX DeviceID DEC Compatible master port type SIO mode support | , V1.1 COM2 (38,4 kBaud) 2.3 ms 16 Bit Bit 0 = switching signal QL1 Bit 1 = switching signal QL2 Bit 2 ... 15 = empty 26 0x800184 8388996 A Yes |
| Supply voltage UB | 10 V DC ... 30 V DC 1) |
| Ripple | ≤ 5 Vpp |
| Usage category | DC-12 (According to EN 60947-5-2) DC-13 (According to EN 60947-5-2) |
| Current consumption | ≤ 30 mA, without load. At UB = 24 V |
| Protection class | III |
| Digital output Number Type | 2 (Complementary) Push-pull: PNP/NPN |
1)
2)
3)
4)
Limit values.
Signal transit time with resistive load in switching mode.
With light/dark ratio 1:1.
This switching output must not be connected to another output.
2)
3)
4)
Limit values.
Signal transit time with resistive load in switching mode.
With light/dark ratio 1:1.
This switching output must not be connected to another output.
| Signal voltage PNP HIGH/LOW Signal voltage NPN HIGH/LOW Output current Imax. Circuit protection outputs Response time Repeatability (response time) Switching frequency | Approx. UB-2.5 V / 0 V Approx. UB / < 2.5 V ≤ 100 mA Reverse polarity protected Overcurrent and short-circuit protected | |
| ≤ 500 µs 150 µs 1,000 Hz | 2) 3) | |
| Pin/Wire assignment Function of pin 4/black (BK) Function of pin 4/black (BK) - detail Function of pin 2/white (WH) Function of pin 2/white (WH) - detail | Digital output, light switching, object present → output QL1 HIGH; IO-Link communication C 4) The pin 4 function of the sensor can be configured, Additional possible settings via IO-Link Digital output, dark switching, object present → output L1 LOW 4) The pin 2 function of the sensor can be configured, Additional possible settings via IO-Link | |
2) Signal transit time with resistive load in switching mode.
3) With light/dark ratio 1:1.
4) This switching output must not be connected to another output.
Mechanical data
| Housing | Rectangular |
| Dimensions (W x H x D) | 24.6 mm x 82.5 mm x 53.3 mm |
| Connection | Male connector M12, 4-pin |
| Material Housing Front screen Male connector | Plastic, VISTAL® Plastic, PMMA Plastic, VISTAL® |
| Weight | Approx. 80 g |
| Maximum tightening torque of the fixing screws | 1.3 Nm |
| Enclosure rating | IP66 (EN 60529) IP67 (EN 60529) IP69 (EN 60529) | 1) |
| Ambient operating temperature | -40 °C ... +60 °C | |
| Ambient temperature, storage | -40 °C ... +75 °C | |
| Shock resistance | 50 g, 11 ms (25 positive and 25 negative shocks per axis, for X, Y, Z axes, 150 shocks in total (EN60068-2-27)) 50 g, 6 ms (5,000 positive and 5,000 negative shocks per axis, for X, Y, Z axes, 30,000 shocks in total (EN60068-2-27)) | |
| Vibration resistance | 10 Hz ... 2,000 Hz (Amplitude 0.5 mm / 10 g, 20 sweeps per axis, for X, Y, Z axes, 1 oc- tave/min, (EN60068-2-6)) | |
| Air humidity | 35 % ... 95 %, Relative humidity (no condensation) | |
| Electromagnetic compatibility (EMC) | EN 60947-5-2 | |
| Resistance to cleaning agent | ECOLAB | |
| UL File No. | NRKH.E181493 & NRKH7.E181493 |
Smart Task
| Smart Task name | Base logics | |
| Logic function | Direct AND OR Window Hysteresis | |
| Timer function | Deactivated On delay Off delay ON and OFF delay Impulse (one shot) | |
| Inverter | Yes | |
| Switching frequency | SIO Logic: 800 Hz IOL: 650 Hz 2) | 1) |
| Response time | SIO Logic: 600 µs 1) IOL: 750 µs 2) | |
| Repeatability | SIO Logic: 300 µs IOL: 400 µs 2) | 1) |
| Switching signal Switching signal QL1 Switching signal L1 | Switching output Switching output | |
2) Use of Smart Task functions with IO-Link communication function.
Diagnosis
| Device status | Yes |
| Quality of teach | Yes |