AG-1K070
Floor Type
Public Use
One Pile with Multiple Charges
≤13kg
>500,000 Hours
Meet CE
0-80A
0.2-80A Continuously Adjustable
20kw
200VDC-1000VDC, Voltage Regulation Step Is 0.1VDC
-40~75
-40~80
Forced Air Cooling
>96%
<5%
OEM
Carton
84mm (height) X218mm (width)X458mm (depth)
Jiangsu
8504409999
Product Description
Wholesale 20kw EV Charging Module for DC Electric Vehicle Charger
Main feature:Ultra-low standby power consumption: less than 9W
Unique three-proof design: unique anti-salt spray, anti-humidity, anti-mildew and other protection and process design, making the module suitable for various charging station application scenarios
Wide temperature range: -40ºC~+75ºC, derated output above +55ºC, suitable for applications in various scenarios
Energy saving and environmental protection: high-efficiency operation in the full load range and ultra-low standby power consumption, the highest efficiency is >97%, effectively reducing energy loss and realizing energy saving and environmental protection
Wide input voltage range: AC 260Vac ~ 530Vac, suitable for various grid environments
Full digital control: Dual DSP design realizes full digital control of the charging module to ensure high reliability of control
Damage-free hot-swap: the module has a real damage-free hot-swap function, plug and play
Battery anti-backfeed: effectively protect the battery while ensuring reliable and safe operation of the system
Application scenario:
DC charging stations for passenger electric vehicles, electric logistics vehicles, electric minibuses, electric buses, and electric engineering vehicles.

| Technical Parameters | ||
| working environment conditions | Operating temperature | -40°C~+75°C, derating above +55°C |
| storage temperature | -40ºC~+80ºC | |
| Relative humidity | ≤95%RH, no condensation | |
| cooling method | forced air cooling | |
| Altitude | 2000m, above 2000m need to consider derating | |
| AC input | Input voltage range | 260Vac~530Vac, three-phase without neutral wire |
| input current | <37A | |
| Frequency Range | 45Hz~65Hz | |
| power factor | ≥0.99 | |
| Efficiency (full load) | >96% | |
| THD | <5% | |
| DC output | Output Power | 20kW |
| voltage range | 200Vdc-1000Vdc, voltage regulation step is 0.1Vdc | |
| Constant power output voltage range | 250Vdc-1000Vdc | |
| Output current | 0-80A | |
| output current limit | 0.2-80A continuously adjustable | |
| current sharing | Unbalance <±5% | |
| Voltage regulation accuracy | <±0.5% | |
| Steady current accuracy | ≤±1% (Output load 20%~100% rated range) | |
| monitor | way of communication | CAN bus |
| indicator light | Green: Normal operation Yellow: Protection alarm Red: Fault alarm | |
| Alarm and Protection | Input over/under voltage protection | Automatic shutdown protection, return to standby after normal input |
| Output overvoltage protection | Automatic shutdown and lock, need to re-power on to resume work | |
| Overcurrent and short circuit protection | Automatic shutdown protection, return to standby state after failure is eliminated | |
| over temperature protection | Automatic shutdown protection, return to standby mode after normal temperature | |
| Product reliability and safety regulations | Mean time between failures (MTBF) | >500,000 hours |
| safety regulations | Meet CE | |