TI-8K
Active Inverter
CCC, ISO9001, RoHS, CE, SAA
>1000W
off-Grid Inverter
Single
Full-Bridge Type
Sine Wave Inverter
DC/AC Inverters
-48VDC
-40~-58VDC
220VAC, 1phase
True Sine Wave
1kVA-5kVA
4u
Electric Power
Telecom
440*500*178mm(W*D*H)/32kg
JETPOWER
Plywood Case
CE
China
85044030
Product Description
8kva / 6.4kw 48V DC to 220 / 230V AC Telecom Inverter
48VDC inverter Features:
(1) Pure sine wave output
(2) High efficiency conversion
(3) Primary DC input and secondary AC input available
(4) Tower or rack-mount convertible
(5) 2U height design
(6) High power, Low profile
(7) Advanced Microprocessor control
(8) Design Provides High Reliability and Efficiency
(9) Over load protection and alarm
(10) Low audible noise: < 55 dB
(11) EMI meet VDE0871 Class A
(12) RS 232 communication
(13) MTBR<1hrs
(14) Dry Contact alarm interface
(15) Fax/ Modem surge Suppression ports
(16) RJ45 Network surge suppression ports
Product images
Specification
48VDC inverter Features:
(1) Pure sine wave output
(2) High efficiency conversion
(3) Primary DC input and secondary AC input available
(4) Tower or rack-mount convertible
(5) 2U height design
(6) High power, Low profile
(7) Advanced Microprocessor control
(8) Design Provides High Reliability and Efficiency
(9) Over load protection and alarm
(10) Low audible noise: < 55 dB
(11) EMI meet VDE0871 Class A
(12) RS 232 communication
(13) MTBR<1hrs
(14) Dry Contact alarm interface
(15) Fax/ Modem surge Suppression ports
(16) RJ45 Network surge suppression ports
Product images
Specification
Model | TI-5K | TI-8K | TI-10K | ||
Capacity | 5KVA/4kW | 8KVA/6.4KW | 10KVA/8KW | ||
Power factor | 0.8 | ||||
Phase | DC input/ Single phase AC output | ||||
Working input voltage | DC 40V-60V | ||||
Output voltage | 230Vac+/-2% (Sinewave) | ||||
THD | <3%(linear load) | ||||
frequency | 50Hz±0.5%(with battery) | ||||
Crest factor | 3:1 | ||||
wave | Sine wave | ||||
Output waveform distortion | Sine wave ,linear load<3%;non-linear load<5% | ||||
Dynamic characteristics | <±5% (0←→ 100%load) | ||||
Recover time | <10ms | ||||
Overload | 125% 1min,150% 3S | ||||
Efficiency | >85%(Full load) | ||||
General Protection | Output Short;Over Voltage; Overload;Low BATT.Voltage | ||||
Communication | RS232/RS485, (SNMP card option) | ||||
Environment require | Temp:-20~40ºC Relative humidity: 0~90%( no coagulation) | ||||
Cooling system | COMPULSIVE VENTILATION(with temperature control) | ||||
Connection | under/back Single phase+N+G | ||||
Dimension(mm)(W*D*H) | 440*500*178(W*D*H) | ||||
Net Weight(kg) | 22 | 32 | 35 |