VTE-ESS30KR50C-NA
Li-ion Battery
LFP
Yes
51.2V 130ah Byd Blade Battery Module
53.248kwh
409.6V
90A
1000kg
V&T
Wood
1360*1300*1950mm(W*D*H)
China
Product Description
..
PV controller modular design, easy to expand
Flexible Battery Type(li-ion,lead-acid)
Smooth switching between on and offgrid, uninterrupted supply of load
Operate with EMS to monitor system status in realtime
Perfect protection function for inverter and battery
Built-in maintenance bypass switch, improve system availability
Battery Input
AC(on-grid)
AC(Off Grid)
General data
Display and Communication





.................................................................
Friendly&flexible
Various working modes can be set flexiblyPV controller modular design, easy to expand
Flexible Battery Type(li-ion,lead-acid)
Intelligent&efficient
Support battery capacity and discharge time predictionSmooth switching between on and offgrid, uninterrupted supply of load
Operate with EMS to monitor system status in realtime
Safe&Reliable
Built-in isolation transformer for high load adaptabilityPerfect protection function for inverter and battery
Abndant configuration
Support simultaneous access of load,battery,power grid , diesel and PVBuilt-in maintenance bypass switch, improve system availability
| Model | VTE-ESS30KR50C-NA | VTE-ESS60KR106C-NA VTE-ESS90KR159C-NA |
| PV Input | ||
| Max. Power(KW) | 45KW | 90KW |
| Max. DC Voltage(V) | 830VDC | |
| MPPT Voltage Range(V) | 200~750 (430~750 @Full Load ) V | |
| MPPT Tracker | 1 | 2 |
| MPPT Strings | 3 | 3+3 |
| Max.Input Current of Each MPPT(A) | 35A/35A/35A | |
| Battery Type | Lithium Iron Phosphate(LiFePO4) | ||
| Battery Module | 51.2V 130AH BYD Blade Battery Module | ||
| Battery Capacity(KWH) | 53.248KWH | 106.496KWH | 159.744KWH |
| Nominal Voltage(V) | 409.6V | 614.4V | |
| Battery Voltage Range(V) | 345.6-486.4V | 518.4-729.6V | |
| Number of Battery Clusters | 1 | 2 | |
| Max. Power(KW) | 33KW | 66KW | 99KW |
| Max. Charge/Discharge Current (A) | 90A | 180A | |
| Max Output Power(KVA) | 33KVA | 66KVA | 99KVA |
| Rated Power(KW) | 30KW | 60KW | 90KW |
| Rated Grid Voltage(V) | 3P3W+PE, 480 (±15%) Vac | ||
| Rated Frequency (Hz) | 60 (±2 .5) Hz | ||
| THDI | <3% | ||
| Power Factor | Listed: 0 8-1 Leading orLagging Actual:0.1~1 Leading orLagging | ||
| Max Output Power(KVA) | 33KVA | 66KVA | 99KVA |
| Rated Power(KW) | 30KW | 60KW | 90KW |
| Rated Voltage(V) | 3P3W+PE, 480 (±5% Configurable) Vac | ||
| Rated Frequency(Hz) | 60 (±5 Configurable) Hz | ||
| Overload Capacity | 110%~120% ,10 mins 120%--130% 1min 130%~150% ,200 ms > 150% 100 ms | ||
| Dimension W*D*H(mm) | 1360* 1300* 1950 | 1360* 1300*2200 | |
| Weight(KG) | About 1000KG | About 1450KG | About 1980KG |
| Operation Temperature | -30ºC to +55ºC | ||
| Relative Humidity | 0 ~95% Non-condensing | ||
| Ingress Protection | IP54 | ||
| Noise Emission(dB) | <70dB | ||
| Altitude | 5 ,000m(>3 ,000 Derating) | ||
| Fire Extinguishing System | Support | ||
| PCS Cooling Way | Intelligent Fan | ||
| Battery Cooling Way | Air Conditioning Cooling | ||
| Display | LCD Touch-screen |
| BMS Communication | RS485/CAN |
| EMS Communication | RS485 , TCP/IP |
| Standard | |
| Inverter Grid Regulation | IEEE1547; UL1741SA; RULE 21 |
| Safety Certification | UL1741; UL9540 |
| EMC Standard | FCC |





.................................................................