CIMR-VCBA0006BAA
with
6 Months
Driving System
Elevator
1000kg
11-20
1.00-2.00m/s
Manual
Microcomputer Frequency Control
Telescoping Lift
Public Traffic
Hollow Guide
1-Phase
200 V
5A
1.7kg
Carton Box
108*128*137.5mm
China
Product Description
Overview
The Yaskawa V1000 is a general-purpose AC drive covering the demands of a wide field of applications including Open-Loop-Vector functionality and the use of PM motors without feedback.
- High flux braking for 50% reduction of braking time
- Online Auto-Tuning to optimize for improved motor performance at low speed
- Open Loop Vector Control for PM motor operation
- Safe Disable Inputs for Safe Torque OFF
Technical Details
- Input Power Supply
- 200 V
- Input Power Phases
- 1-phase
- Rated Output Current (Heavy Duty)
- 5 A
- Rated Output Current (Normal Duty)
- 6 A
- Max. Applicable Motor Power (HD)
- 0.75 kW
- Max. Applicable Motor Power (ND)
- 1.1 kW
- Motor Type
- Permanent magnet motor, Induction motor
- EMC Filter
- x No
- Standards Compliance
- cUL, CE, RoHS, UL
- Ambient Temperature (Min)
- -10 °C
- Ambient Temperature (Max)
- 50 °C
- Max. Humidity (non-condensing)
- 95 %
- Max. Altitude (without Derating)
- 1,000 m
- Max. Altitude (with Derating)
- 3,000 m
- Height
- 128 mm
- Width
- 108 mm
- Depth
- 137.5 mm
- Weight
- 1.7 kg
- Enclosure
- IP20/UL Open Type
- Environmental Specifications
- Standard
About us:
Why choose us?
Shanghai Sunny Elevator Co., Ltd, founded in 1992, is a 32-year professional manufacturer specializing in designing and producting Opto-Electro-Mechanical products.
Sunny Elevator has started import and export since 2012.
We have experience in exporting all kinds of elevator parts and complete elevator to 80 countries all over the world.
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won't break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.