AS180 Fan & Pump Drives
Power input | Input Voltage | 380-460V (-15% ~ + 10%), three-phase |
Input Frequency | 45-65Hz | |
Allowable voltage fluctuation | Voltage unbalance <3% | |
Instant-drop | Three-phase AC380-460V power supply, under voltage protection will work in 15ms if the input voltage is lower than AC300V | |
Power output | Voltage | 0 VAC ~ Input voltage |
Overload Class | Stable working in the case of 40 ºC, heavy duty 150%, 1min | |
Efficiency (full load) | ≥0.94 | |
Output frequency accuracy | ± 0.01% (digital command -10 ~ + 45 ºC) ; ± 0.1% (simulation instruction 25 ± 10 ºC) | |
Digital I / O | Opto-isolated input | 7 channels, 24V high active low can be set, input function can be defined |
Open collector | 2 channels, Output functions can be defined | |
Relay output | 2 channels, normally open contacts, contact capacity: inductive, 1.5A / 250VAC, output function defined | |
Analog I / O | Analog Input Voltage | 2 channels, accuracy 0.1%; Voltage:-10V~ + 10VDCOr Current: 0-20mA optional signal |
Analog voltage output | 2 channels, accuracy 0.1%; Voltage:-10V~ + 10VDCOr Current: 0-20mA optional signal | |
Control characteristics | Carrier frequency | 1.1-8 kHz; load characteristics, the carrier frequency can be automatically adjusted |
Frequency setting resolution | 0.01Hz (digital command),± 0.06Hz / 120Hz (11bit + unsigned analog instruction) | |
Run command channel | operation panel, control terminal, communication | |
frequency Setting channel | operation panel, digital/analog input, communication, performance function setting | |
Torque boost | Automatic torque boost; Manual torque boost | |
V/F curve | V/F Curve linear V/F And three curves of torque-derating can be defined | |
Automatic voltage regulation (AVR) | The output PWM can be Automatically adjusted according to the fluctuation of the bus, thereby reducing the influence of voltage fluctuations of the output voltage ripple | |
non-stop operation | in case of instant power failure, uninterrupted operation can be guaranteed by controlling the bus voltage | |
DC braking capacity | Braking current:0.0~120.0% Of rated current | |
Special feature | Parameter copy | Parameter upload and download can be achieved via operating panel with the progress bar |
Process PID | It can be used for closed-loop control of the process | |
Common DC bus | Full power range supports the common DC bus | |
Motor protection | Locked rotor | |
Motor overload | ||
Speed limit | ||
Frequency Drive protection | Output current limit | |
Inverter overload | ||
IGBT I²t overload | ||
Input Supply Undervoltage / Overvoltage | ||
DC bus under-voltage / overvoltage | ||
IGBT overheating | ||
Radiator overheating | ||
electricity failure |
Our hot products:
![](https://image.cautop.com/365f3j00cGslrhBgguoV/As180-Fan-Pump-Drives-with-45-65Hz-Input-Frequency.jpg)
![](https://image.cautop.com/365f3j00qGjhzBCbZgkl/As180-Fan-Pump-Drives-with-45-65Hz-Input-Frequency.jpg)
![](https://image.cautop.com/365f3j00SFGosnBlPikN/As180-Fan-Pump-Drives-with-45-65Hz-Input-Frequency.jpg)
![](https://image.cautop.com/365f3j00FNfqsEMULloy/As180-Fan-Pump-Drives-with-45-65Hz-Input-Frequency.jpg)
About us:
![](https://image.cautop.com/365f3j00qmCiSadrlkcp/As180-Fan-Pump-Drives-with-45-65Hz-Input-Frequency.jpg)
Why choose us?
Shanghai Sunny Elevator Co., Ltd, founded in 1992, is a 31-year professional manufacturer specializing in designing and producting Opto-Electro-Mechanical products.
Sunny Elevator has started import and export since 2012.
We have experience in exporting all kinds of elevator parts and complete elevator to 80 countries all over the world.