TH750Q
One Pile with Multiple Charges
Public Use
Floor Type
Quick Charge
CE, ISO
TONHE
China
8504401990
Product Description
Input features
Item | Parameters | Remark |
Operating Voltage(AC) | 285~475V,rated voltage380V | See input voltage/output power 1.3.3-1 |
Input Frequency(HZ) | 45~55 | |
Power Factor | Full load≥0.99 | |
THD | Full load≤5% | |
Standby Power Consumption | <12W |
Input voltage/output power curve
![](https://image.cautop.com/365f3j00MZwYnqksejzA/Charging-Module-EV-Charger-EV-Charging-Module-DC-Power-Supply-Power-Supply-AC-to-DC-Module-Battery-Charger-Power-Module-AC-DC-Conversion-Module.jpg)
Output Feature
Item | Parameter | Remark |
Output Voltage Range(DC) | 150~1000V | |
Max output current(A) | 120 | |
Output constant power interval | 250~500VDC,500~1000VDC | |
Output current limit range | Max limit current is120A,limit current point can be set between 2~120A | See output voltage/current curve 1.3.3-2 |
Voltage Stabilization Accuracy | ≤±0.5% | |
Current Stabilization Accuracy | ≤±1%(load current is in the range of 20%~100%) | |
Effective value coefficient of output ripple | ≤±0.5% | |
Current sharing imbalance for modules in parallel | ≤±5%(parallel average current should be more than 5A) | |
Peak efficiency | ≥95.5% | |
Soft start time(S) | 3~8 | |
When output, prevent current rewinding | Support | |
Communication Protocol | CAN |
Output voltage/output current
![](https://image.cautop.com/365f3j00BjmUNZclcSrd/Charging-Module-EV-Charger-EV-Charging-Module-DC-Power-Supply-Power-Supply-AC-to-DC-Module-Battery-Charger-Power-Module-AC-DC-Conversion-Module.jpg)
CE CERTIFICATE
![](https://image.cautop.com/365f3j00SjdYnGqIwZpJ/Charging-Module-EV-Charger-EV-Charging-Module-DC-Power-Supply-Power-Supply-AC-to-DC-Module-Battery-Charger-Power-Module-AC-DC-Conversion-Module.jpg)
Manufacturing Center
![](https://image.cautop.com/365f3j00jSAUyZkziKrw/Charging-Module-EV-Charger-EV-Charging-Module-DC-Power-Supply-Power-Supply-AC-to-DC-Module-Battery-Charger-Power-Module-AC-DC-Conversion-Module.jpg)
Test Center
18m³ walk-in high and low temperature lab
![](https://image.cautop.com/365f3j00FZdUNRbYySuA/Charging-Module-EV-Charger-EV-Charging-Module-DC-Power-Supply-Power-Supply-AC-to-DC-Module-Battery-Charger-Power-Module-AC-DC-Conversion-Module.jpg)
Anechonic Chamber Designed and contracted to build by Germany FARNKONIA,meeting testing place requirements of CISPR22\CISPR24,IEC61000-4-3,ISO 11452-2,ISO 11452-4,GJB151A/GJB152B
![](https://image.cautop.com/365f3j00yZwYNHcFKKgJ/Charging-Module-EV-Charger-EV-Charging-Module-DC-Power-Supply-Power-Supply-AC-to-DC-Module-Battery-Charger-Power-Module-AC-DC-Conversion-Module.jpg)
Test hall:program AC power supply,DC electronic load,power quality analyzer,300KVA adjustable AC power supply and so on.
![](https://image.cautop.com/365f3j00yKwUOskZtjum/Charging-Module-EV-Charger-EV-Charging-Module-DC-Power-Supply-Power-Supply-AC-to-DC-Module-Battery-Charger-Power-Module-AC-DC-Conversion-Module.jpg)