Hot Search: perfume  lining  mr333501  205/75r17.5  250cc motorcycle  truck tire  atv quad  atv tire  car lift  cargo trailer 

New 40' Tank Container, Cryogenic Tanker Container, Container Tanker

Supplier Henan Jushixin Transportation Equipment Co., Ltd.
Price $78000.00 / Piece
Availability In Stock
Mini Order:
+-
Subtotal: $78000

Purchase details

Payments:

Tax:

Tax Included 

Returns&Refunds:

Eligible for refunds within 30 days of receiving products. returns and refunds 

 
Model NO.
JSXT40455LTC ISO Containers for LNG
Experice
10 Years
Producing Period
>20 Days
Frame Size
40feet ISO Tank Container
Life Span
<25 Years
Color
Customized
Loading Capacity
25000L for 40feet ISO Tank Container
Maximum Gross Weight
35000 Kg for 40feet ISO Tank Container
Tare
8600 Kg for 40feet ISO Tank Container
Design Temperature(ºC)
55 for 40feet ISO Tank Container
Operating Temperature(ºC)
-40~50 for 40feet ISO Tank Container
Filling Medium
1, 2-Tetrafluoroethane
Tank Instruction
T75 for 40feet ISO Tank Container
Max. Payload (Kg)
22568 for 40feet ISO Tank Container
Hydro.Test Pressure(MPa)
2.18 for 40feet ISO Tank Container
Leakage Test Pressure(MPa)
1.38 for 40feet ISO Tank Container
Transport Package
by Container Vessel for This Tanker Container
Specification
12460*2500*3980/mm carbon steel tanker
Trademark
JUSHIXIN
Origin
Mainland of China
HS Code
8609001200
Production Capacity
200units/Month for 40feet ISO Tank Container
Type:
ISO Tank Container
Certification:
ISO9001, ECE, CE
Volume:
5.89M * 2.32M * 2.31M
Material:
Carbon Steel for ISO Tank
Length:
40′
Gross Weight:
30.4T
40Feet 40.44CBM T75 LNG/LO2/LCO2/LIN/LOX/LAR/Liquid Ammonia/Liquid Argon Cryogenic ISO Storage Tank Container

1. The functions of this series container tanker/tank container:
***This series tank semi trailers are suitable for the transportation 1,1,1,2-Tetrafluoroethane,LNG/LO2/LCO2/LIN/LOX/LAR/Liquid Ammonia/Liquid Argon,Etc. Gas.
*** The volume is under 50 cube meters, we can manufacture it according to your needs.


2.The related Specification for this container tanker/tank container:
Dimension of the 40FT 40.44CBM LNG Tank Container with BV&T75
Description and Specification of Commodity
Codes and regulations for this Tank containerTSG R0005-2011 <Mobile Pressure Vessel Safety Technical Inspection Regulations>, "International Maritime Dangerous Goods Code" (IMDG CODE)
JB / T4780-2002 "Liquefied Natural Gas Tank Containers", Container Inspection Code-2012
Guidelines for tank container for this Tank containerT75
Container Type for this Tank container1AA
Rated weight for this Tank container32723kgs
Maximum Allowed Loading Weight for this Tank container14700kgs
Tare weight for this Tank container18023kgs
Allowed stacking weight for this Tank container192000kgs
Manufacturing license level for this Tank containerInside tankC3
outside tank
Max. Working Pressure(Mpa.) for this Tank containerInside tank(MPa)0.7 
outside tank(MPa)-0.1(Vacuum)
Min. Working Tempretrues for this Tank containerInside tank-162 °C
outside tank-20°C
Design Pressure(Mpa.) for this Tank containerInside tank0.8 
outside tank-0.1/0.2
Design Tempretrues for this Tank containerInside tank-196 °C
outside tank50 °C
The Main material for this Tank containerCoverinside tankS30408
outside tankQ345R
Shellinside tankS30408
outside tankQ345R
Overall Size(Frame)/L*W*H/mm for this Tank container12192*2438*2591
Media for this Tank containerInside tankLNG
Media Characteristics for this Tank containerInside tankexplosive
Paint for this Tank containerFrame 30µm +40µm +50µm 
Shell30µm +40µm +50µm 
Total Volume(L) for this Tank container40440
Effective volume(L) for this Tank container36400
Rated filling rate for this Tank container90%
Corrosion allowance for this Tank containerInside tank0mm
outside tank1mm
Air tightness test pressure(Mpa) for this Tank containerInside tank0.8mm
outside tank0.2mm
Air pressure test pressure for this Tank containerInside tank(MPa)0.92
Welding joint coefficient for this Tank containerInside tank1
outside tank0.85
Static evaporation rate for this Tank containerInside tank<=0.18
Material density(kg/m3) for this Tank containerInside tank426
Natural boost rate for this Tank containerInside tank<=13
Main hazard category for this Tank container2.1
Design service life for this Tank container 15 years
Mode of transportation for this Tank containerRoad,Sea or Railway
Adiabatic form for this Tank containerHigh vacuum multilayer insulation
 Emergency cut-off valve for this Tank containerTypeGas phaseKDJ661F-16P
liquid phaseKDJ661F-16P
Nominal pressureGas phase(Mpa)1.6
liquid phase(Mpa)1.6
Nominal DiameterGas phaseDN50/DN32
liquid phaseDN50
Operation wayGas phasePneumatic motion control
liquid phasePneumatic motion control
Fusible temperature for the Fusible alloy of the fusible plug(°C)70+/-5
Safety valve for this Tank containerTypeZA25-5B
ModeLow temperature modular safety valve
Level gauge for this Tank containerTypeZK-1.5-6-1
MouldCYJ-1 Double liquid column pressure difference level gauge
Nominal pressure(Mpa)1.6
Nominal DiameterDN6
Measuring range(Kpa)0~15
Precision>=2.5
Loading and unloading device for this Tank containerGas phase jointTypeFlange connection
Nominal DiameterDN50
liquid phase jointTypeFlange connection
Nominal DiameterDN50
Pressure gauge for this Tank containerTypeYN-100
Measuring range(Mpa)0~1.6
Precision1.6 Class
Shell blasting device for this Tank containerBurst pressure(Mpa)<=0.1
Nominal DiameterDN80
TypeYEJ80-0.1-50
Orifice table
symbolNominal  SizeNominal  PressureTube SizePurpose and NameConnection standard and Type
CZ15040Ø57*3.5liquid phase entranceHG/T20592-2009
CZ25040Ø57*3.5Gas phase entranceHG/T20592-2009
CZ33240Ø38*3Supercharger liquid phase entranceHG/T20592-2009
j80//Shell explosion-proof port/
Technical Requirements
1.This frame tank container should carry out all kinds of the test according to the GB / T16563-1996 and China Classification Society "Container Inspection Code".                                                    
2.Except for the pictures' mark, the type and size of the welded structure shall be in accordance with GB / 985.1. The height of the weld foot and weld fillet is according to the thickness of the less thinner steel plate.There should not be crack, slag, porosity, or undercut, etc. on the surface of the welded joint.Weld seam surface will be inspected through the magnetic powder or penetration testing (preferred magnetic powder). Meet NB / t47013.4 (5) -2015, Class I qualified.
3.The accessories shall meet the corresponding standards of product quality certification,which can be carried out the air tightness test together with the tank after passing the re-examination and form a complete set then delivery from the factory;
4Valve opening operation,should be able to withstand the pressure of the air tightness test , fully open, fully closed, flexible operation, no abnormal resistance, idling and so on;
5All signs, brand names, stickers will be made according to the drawings after the competion of the painting; The area around the signs, brand names and rivets will be sealed with the sealant.
6The vertical plane of the longitudinal centerline of the tank shall be coincident with the vertical plane of the longitudinal centerline of the frame. The offset shall not exceed 5mm.
77. All supports of the connections between the tank and the frame should be thin welding, and welding firm and reliable, the weld seam surface shall not have cracks, undercut, stomatal, crater and splash.

 
88. Tank coating in line with the relevant provisions of JB / T4711-2003. After complete cleaning the rust of the outside carbon steel surface of the tank,coated two anti-rust primer, two white finish.
99. The tank container needs to be replaced with nitrogen or vacuumed before leaving the factory.
(1) the use of nitrogen replacement treatment, the oxygen content after treatment is less than 3%, and keep the residual pressure 0.05Mpa ~ 0.1Mpar;
(2) the use of vacuum treatment, the vacuum after treatment is not less than 0.086Mpa.
1010. Emergency cut-off device should be installed before the air tightness test, the test medium is air, the test pressure is 0.1Mpa;After the installation is complete, Emergency shut-off device should be done through emergency cut off and filter protection test, gas valve, liquid valve and booster valve completely closed in 5S qualified, air source control valve rotation flexibility, no jamming phenomenon.

3.Some photos for our ISO Storage Tank Container Workshop:
New 40&prime; Tank Container with Competitive Price
4.Detailed photos for the Gas Tank Container:
New 40&prime; Tank Container with Competitive Price


The Valves for this tank container are all imported from the U.K.
New 40&prime; Tank Container with Competitive Price

5.Our customer testing the Air tightness for the gas tank container by themselves
New 40&prime; Tank Container with Competitive Price

New 40&prime; Tank Container with Competitive Price

6.FlEXIBLE SERVICE WE PROMISED FOR EACH ITEM FROM OUR FACTORY:
>>>Offering the one-stop full lifecycle services;
>>>Our vehicle users will receive 24-hour uninterruptible "Entire Journey" service;

>>>CCC&ISO Agreement, 1 Year Guarantee Term, Main-beam Lifetime Promise;
>>> Small Order Can Be Accepted;
>>>Any Color & Logo Available;
>>>The Product Dimension + Specifications Can Be Designed As Your Needs.


7.More styles for this ISO LNG Storage Tank Container
New 40&prime; Tank Container with Competitive Price



8.Buying Guides for this ISO Storage Tank Container
**You please send us your enquiry;
**We shall reply you with the quotation within 12 hours;
**We negotiate on the configuration that you need;
**Confirmation of the tech data → sign contract (P/I) → 30% deposit (or L/C issuing)→ production;
**Manufacturing process updated news → completing production;
**Balance payment → ex works → shipment → custom clearance → A/S service for 1 year.

 
>>>Contact information for this tank container
Maggie Suen
Office.:+86-371-55628659                    
Mobile:+86-13838278359
Website: cautop.com/store/hnjsx-trailer
Send Message
Message Type
*Content
Your Name  
Tel
*Email
* Captcha  
You May Like