Production Capacity
1000000meters/Month
Suitable for:
Elevator
Transport Package:
Reel/Carton
Product Structure | |||||||||||||||||||||||||||||||||||
Conductor: | Comply with GB/T3956-1997 5kinds conductor specification requirement. following DIN VDE 0295 and IEC 228 standard twisted copper wires | ||||||||||||||||||||||||||||||||||
Conductor insulation: | PVC/D type | ||||||||||||||||||||||||||||||||||
Conductor colors: | Conductor inuslation color more than 5 cores following GB5023.1-2012 4.2 | ||||||||||||||||||||||||||||||||||
Conductor structure | Insulation core stranding, grouping seriation | ||||||||||||||||||||||||||||||||||
Outer Jacket | PVC/ST5 cold-resistant special sheath,Black(RAL9005)or grey(RAL7001) | ||||||||||||||||||||||||||||||||||
Standards: | GB5023.6-2012 / 60227 IEC 71f(TVVB) |
Technical Specification | ||||||||||||||||||||||||
Rated Voltage: | U0/U 300/500V | |||||||||||||||||||||||
Test Voltage: | Insulation thickness≤0.6:1500V,finished product test:2000V. | |||||||||||||||||||||||
Operating Temperature | -15ºC~+70ºC | |||||||||||||||||||||||
Minimum Bending Radius | Cable installtion allowed bending radius should no less than 6 times of cable width | |||||||||||||||||||||||
Static bending test | According to GB5023.2-2012 3.5 | |||||||||||||||||||||||
Flame resistance | Pass GB/T18380.1-2001 test and GB5023.6-2012 |
Special Characteristics |
Special Characteristics:Cable softness is good,free hanging length no more than 35 meters, and moving speed no more than1.6m/S.Conductor maximum temperature is 70ºC, normal working temperature is -15ºC~40ºC. |
Approvals And Standards:CE/ROHS/CCC |
Application: Apply for the elevator internal traveling suspension cable |
Send Message