Model NO.
Bed Lift
Driving Type
AC Elevator
Capacity
>1000kg
Persons
>20
Speed
<1.00m/s
Control Mode
Signal Control
Position of Computer Room
up
Elevator Door
Center Opening Door
Door Knife
Single
Deceleration Device
With Deceleration Device
Control System
Monarch
Date of Delivery
30days-45days
Car Position Indicator
LCD Display/DOT-Matrix Display
Light Supply
1 Phase, 220V, 50Hz
Drive
Vvvf Inverter Driving System
Trademark
general brand
Transport Package
High Quality Export Wooden Case
Specification
1*20GP
Origin
China
HS Code
84281010
Product Description
Rescue Stretcher Bed Lift Hospital Elevator for disabled
Product Application
Hospital elevator have high performance elevator parts, permanent magnet synchronous drive and intelligent door
system, safe and reliable.
Hospital elevator permanent magnet synchronous traction machine,smaller volume but higher efficiency, saving
more space for the headroom.
Hospital elevator highest safty standard, to ensure passenger safty.
Hospital elevator multiple customized for the transportation arrangement and structure for matching the design style of house.
capacity | speed | Car size | Door size | Machine room size | Min net height of overhead | Nei pit depth | ||
Door size | ||||||||
kg | M/s | Inner size | HW*HD | MRW*MRD*HM | OH(mm) | PP(mm) | type | JJ*HH(mm) |
1 | 4600 | 1700 | Two pcs side open | |||||
1600 | 1.5 | 4700 | 1800 | 1200*2100 | ||||
1.75 | 1400*2400 | 2400*3000 | 2400*5000*2800 | 4800 | 1900 | Two pcs center open | ||
1100*2100 |
Safety | |
Safety gear | Progressive Safety gear |
Buffer | Polyurethane buffer |
Speed governor | Bidirectional governor |
Standard Function | |
Automatic return to main floor | Alarm Bell |
Light curtain | Door closing overtime protection |
Parking operation | Emergency firemen operation |
Parallel operation for two elevators | Emergency car light |
Motor temperature protection | Full collective operation |
Fire signal feedback | Hall & car call register |
Car arrival chime | Hall & car direction indicator |
Five-way intercom (Not containing the connection line from the machine room to the monitoring room) | Protection of door-lock disconnect when running |
Non-stop when full load | Non-open outside door zone |
Overload warning | Pre-torque output |
Trip count | Voltage wavy detection |
level to nearest floor when malfunctioning | Contactor feedback |
Ventilation manual and lighting automatic control | Relay detection |
Faulty automatic detection | Speed detection |
Select floor in the controller | Automatically eliminate reverse instruction |
Landing call button embedded self-diagnosis | Repeated door closing |
Setting non-stop floor | Hoistway self-learning |
Reserve running protection | Safety circuit protection |
Anti-slip protection | Limit switch protection |
Up & down final limit protection | Independent running |
Brake detection | Running contactor protection |