Model NO.
BMEV3.0
Driving Type
AC Elevator
Capacity
450-1600kg
Persons
6-22
Speed
1.00-2.50m/S
Control Mode
Collective Selective Control
Position of Computer Room
up
Elevator Door
Center Opening Door
Door Knife
Single
Deceleration Device
With Deceleration Device
Attendant
with or Without Waiter
Production Time
15~30 Days
Main Power
AC 380V, 3 Phase 50Hz
Door Open Way
Center Open, Side Open
Control
Blue Light/Monarch
Material
HSS, Mirror, Etching
Control System
32 Bit Microprocessor
Warranty
12 Months in Free
Traction Machine
Gearless
Trademark
Bester
Transport Package
1 Set One 20FT Container
Specification
ISO9001: 2008, ISO14001: 2004, GB/T28001-2011, CE
Origin
Prc
HS Code
84281010
1. Small Machine Room Passenger Elevator Lift
2. Main Specification
Note: the parameter table shows the standard design of our elevator. We also can design elevator for you with your parameter.
No. | Standard Function |
1 | Motor overcurrent protection |
2 | Motor overload protection |
3 | Drive module overheated protection |
4 | Encoder trouble protection |
5 | Power phase fault inspection |
6 | Contactor contact detection protection |
7 | Limit switch protection |
8 | Over speed protection |
9 | Landing switch error protection |
10 | CPU fault protection |
11 | Anti-slippery protection |
12 | Reverse running protection |
13 | Non-opening protection outside of door area |
14 | Overload protection |
15 | Door light curtain protection |
16 | Governor tension detection |
17 | Car top emergency stop switch |
18 | Pit emergency stop switch |
19 | Pit emergency stop switch |
20 | Inspection travel |
21 | Direct landing |
22 | LED lighting |
23 | Fault history record |
24 | Driver operation |
25 | Emergency return during fire |
26 | Floor No. & running direction display |
27 | Independent travel |
28 | Automatically return base floor |
29 | Complete collective selective |
30 | Locking device |
31 | Full-load bypass |
32 | Power saving of lighting and fan |
33 | Out call adhesive identification |
34 | Door pre-closing |
35 | Cancel wrong instructions |
36 | Cancel internal reverse instructions |
37 | Open the door from the landing door |
38 | Change landing position |
39 | Repeat closing |
40 | Internal emergency lighting |
41 | Intercom device |
MAIN SPECIFICATION | |||||||||||
Name of the equipment: | Passenger Elevator | ||||||||||
Lift style: | BMEV3.0 | ||||||||||
Door at different floor: | All doors face to the same direction | ||||||||||
Base floor: | |||||||||||
Operating system: | Fully computerized and elective manner | ||||||||||
Control system: | modularized and fully computerized control system; serial link communication system. | ||||||||||
Driving system: | the new type of BESTER alternating current variable frequency and variable voltage(VVVF) driving system with stepless (infinitely) variable speed | ||||||||||
Door operating system: | BESTER door operating system with the function of variable frequency | ||||||||||
The location of traction machine: | Above the hoistway | ||||||||||
DEVICES OF LADING DOOR | |||||||||||
Material of landing doors: | First floor is airline stainless steel, others are painted steel doors | ||||||||||
Material of landing door jambs: | First floor is airline stainless steel standard jamb, others are painted steel doors standard jamb | ||||||||||
Display unit of landing door: | Adopting the advanced BESTER technology, -the digital display of the car location and running direction in the way of arrowhead (↑↓) | ||||||||||
Hall call device: | Adopting the advanced BESTER technology, -the coverplate is made of hairline finished stainless steel; microbutton; LED dot-matric display |
DEVICES OF CAR | |||||||||||
Car size: | 1100mm*1100mm | ||||||||||
Decoration of car walls: | Rear wall/Side walll: Stainless steel ; Front: Hairless stainless steel | ||||||||||
Decoration of car ceiling: | Hairless stainless steel | ||||||||||
Mirror: | Not including | ||||||||||
St steel Handrail Number: | Not including | ||||||||||
Car platform: | PVC | ||||||||||
Material of car door: | Hairline stainless steel | ||||||||||
Lighting: | Sunlight illumination | ||||||||||
Ventilating facilities: | Air blower with micro noise | ||||||||||
Communication facilities: | Concealed interphone | ||||||||||
Inspection facilities: | Under the car operating box | ||||||||||
Display unit inside the car: | The digital display of the car location and running direction in the way of arrowhead (↑↓) | ||||||||||
Hall call device inside the car: | The coverplate is made of hairline stainless steel; microbutton; LED dot-matric display | ||||||||||
The way of opening: | Center opening door | ||||||||||
POWER SUPPLY | |||||||||||
Power Source: | 380V±10%; 50Hz±2%; 3 phases 5 lines; neutral line and earth line are always separated | ||||||||||
Lighting: | 220V ;50Hz; single phase |
Note: the parameter table shows the standard design of our elevator. We also can design elevator for you with your parameter.
Bester R&D dep. and Sales(after-sales) dep.
Some our sole agency visit BesterShipping goods photos