Model NO.
NT-S
After-sales Service
Whole Life of The Machine
Warranty
Whole Life of The Machine
Testing Equipment Type
Car Fault Detector
Certification
CE, ISO
Update Method
by Internet
Condition
New
Standard
Standard
Trademark
NANTAI
Transport Package
Package
Specification
3CBM
Origin
Taian, China
HS Code
9031809090
The NT-S fuel metering valve flow performance test bench is the latest intelligent automatic testing equipment developed by our company. It mainly detects the current-flow characteristics of the fuel metering unit components of the high pressure common rail pump. The product adopts Taiwan Advantech industrial computer, touch screen, PLC and other precision control pressure and current. German high-precision flow sensor measures the flow of each point, fast pressure regulation, accurate measurement, and has multiple protection measures such as infrared detection and safety light curtain. Complete testing solutions for pre-research and factory inspections of metering valves and related product manufacturers.
The main function:
- PWM pulse width modulation output drive signal, measuring the flow rate of the metering valve when the oil pressure is stable at 5±0.1bar;
- It can test the normally open and normally closed metering valves of various structural forms and sizes.
- automatically collect, process and draw the metering valve current / flow curve, generate data report
- can meet the manual adjustment of current, current-flow test for fixed points
- Automatically judge whether the pressure, flow rate and loop difference of each measuring point of the metering valve component are qualified.
- with continuous testing, single point testing, standard recording, reliability fatigue running and other functions
- with standard database preparation, storage, upload, statistics, call, print and other functions;
- working power: 380V/50hz
- working pressure: 0-10bar adjustable, accuracy ± 0.01bar
- current adjustment range: 0-3A, accuracy 0.001A
- flow measurement range: 1-1000ml / min, accuracy 0.1ml
- automatic temperature control: 40 ± 2 ° C, can be set