16 AWG 1 PAIR THERMOCOUPLE SOLID KX PVC FOIL SHIELD PVC JACKET POWER LIMITED TRAY CABLE INSTRUMENT TRAY CABLE
Our mill mainly manufacture type KX,,EX,JX,TX,SC/RC,KCA,KCB compensating wire for thermocouple, and they are used in temperature measurement instruments and cables. Our thermocouple compensating products are all made abiding by GB/T 4990-2010 'Alloy wires of extension and compensating cables for thermocouples' (Chinese National Standard), and also IEC584-3 'Thermocouple part 3-compensating wire' (International standard).
The representing of the comp. wire: thermocouple code+C/X , e.g. SC, KX
X: Short for extension, means that the compensation wire's alloy is as the same as the the alloy of the thermocouple
C: Short for compensation, means that the compensation wire's alloy has similar characters with the thermocouple's alloy in a certain temperature range.
Thermocouple Code | Comp. Type | Comp. Wire Name | Positive | Negative | ||
Name | Code | Name | Code | |||
S | SC | copper-constantan 0.6 | copper | SPC | constantan 0.6 | SNC |
R | RC | copper-constantan 0.6 | copper | RPC | constantan 0.6 | RNC |
K | KCA | Iron-constantan22 | Iron | KPCA | constantan22 | KNCA |
K | KCB | copper-constantan 40 | copper | KPCB | constantan 40 | KNCB |
K | KX | Chromel10-NiSi3 | Chromel10 | KPX | NiSi3 | KNX |
N | NC | Iron-constantan 18 | Iron | NPC | constantan 18 | NNC |
N | NX | NiCr14Si-NiSi4Mg | NiCr14Si | NPX | NiSi4Mg | NNX |
E | EX | NiCr10-Constantan45 | NiCr10 | EPX | Constantan45 | ENX |
J | JX | Iron-constantan 45 | Iron | JPX | constantan 45 | JNX |
T | TX | copper-constantan 45 | copper | TPX | constantan 45 | TNX |
1. Chemical Composition
Material | Chemical composition (%) | ||||
Ni | Cr | Si | Mn | Al | |
KP(Chromel) | 90 | 10 | |||
KN(Alumel) | 95 | 1-2 | 0.5-1.5 | 1-1.5 |
2. Physical properties and Mechnical properties
Material | Density(g/cm3) | Melting point(ºC) | Tensile Strength(Mpa) | Volume resistivity(μΩ.cm) | Elongation rate (%) |
KP(Chromel) | 8.5 | 1427 | >490 | 70.6(20ºC) | >10 |
KN(Alumel) | 8.6 | 1399 | >390 | 29.4(20ºC) | >15 |
3. EMF Value range at different temperature
Material | EMF value Vs Pt(μV) | |||||
100ºC | 200ºC | 300ºC | 400ºC | 500ºC | 600ºC | |
KP(Chromel) | 2816~2896 | 5938~6018 | 9298~9378 | 12729~12821 | 16156~16266 | 19532~19676 |
KN(Alumel) | 1218~1262 | 2140~2180 | 2849~2893 | 3600~3644 | 4403~4463 | 5271~5331 |
EMF value Vs Pt(μV) | ||||
700ºC | 800ºC | 900ºC | 1000ºC | 1100ºC |
22845~22999 | 26064~26246 | 29223~29411 | 32313~32525 | 35336~35548 |
6167~6247 | 7080~7160 | 7959~8059 | 8807~8907 | 9617~9737 |
Type K Extension Cable Chromel / Alumel Material FEP insulation
Specifications
1.Style:Extension Wire
2.Thermocouple copper wire
Thermocouple copper wire Classification
1. Thermocouple level (high temperature level). This type of thermocouple wire is mainly suitable for thermocouple type K, J, E, T, N and L and other high temperature detection instrument, temperature sensor, etc.
2. Compensating wire level (low temperature level). This type of thermocouple wire is mainly suitable for compensating cable and extension wire of various thermocouples of type S, R, B, K, E, J, T, N and L, heating cable, control cable and so on.
Thermocouple variety and index
Thermocouple Variety and Index | ||
Variety | Type | Measurement Range(°C) |
NiCr-NiSi | K | -200-1300 |
NiCr-CuNi | E | -200-900 |
Fe-CuNi | J | -40-750 |
Cu-CuNi | T | -200-350 |
NiCrSi-NiSi | N | -200-1300 |
NiCr-AuFe0.07 | NiCr-AuFe0.07 | -270-0 |
3 . Dimensions and Tolerance of Fiberglass Insulated Thermocouple Wire
Dimensions / Tolerance mm ) : 4.0+-0.25
Color code & initial calibration tolerances for thermocouple wire:
Thermocouple Type | ANSI Color Code | Initial Calibration Tolerances | ||||
Wire Alloys | Calibration | +/- Conductor | Jacket | Temperature Range | Standard Limits | Special Limits |
CHROMEL(+) vs. ALUMEL(-) | K | Yellow/Red | Brown | -200°C to -110°C -110°C to 0°C 0°C to +285°C 285°C to +1250°C | ± 2% ±2.2°C ±2.2°C ± .75% | ±1.1°C ± .4% |
Color Code & Initial Calibration Tolerance for Extension Wire:
Extension type | ANSI Color Code | Initial Calibration Tolerances | ||||
Wire Alloys | Calibration | +/- Conductor | Jacket | Temperature Range | Standard Limits | Special Limits |
Iron (+) vs. Constantan(-) | JX | White/Red | Black | 0°C to +200°C | ±2.2°C | ±1.1°C |
CHROMEL (+) vs. ALUMEL (-) | KX | Yellow/Red | Yellow | 0°C to +200°C | ±2.2°C | ±1.1°C |
Copper(+) vs. Constantan(-) | TX | Blue/Red | Blue | -60°C to +100°C | ±1.1°C | ± .5°C |
CHROMEL(+) vs. Constantan(-) | EX | Purple/Red | Purple | 0°C to +200°C | ±1.7°C | ±1.1°C |
PVC-PVC Physical Properties:
Characteristics | Insulation | Jacket |
Abrasion Resistance | Good | Good |
Cut Through Resistance | Good | Good |
Moisture Resistance | Excellent | Excellent |
Solder Iron Resistance | Poor | Poor |
Service Temperature | 105ºC continuous 150ºC single | 105ºC continuous 150ºC single |
Flame Test | Self-extinguishing | Self-extinguishing |
Insulation:Silicone
Choice of Black, Orange, Red or Yellow Blue jacket, single & double insulated.
SQ MM sizes (European style) :4 sq mm to 240 sq mm
AWG sizes (North American style) :0AWG-10AWG,
Wide temperature range: -60°C to 200°C
Insulation:Silicone
Choice of Black, Orange, Red or Yellow Blue jacket, single & double insulated.
SQ MM sizes (European style) :4 sq mm to 240 sq mm
AWG sizes (North American style) :0AWG-10AWG,
Wide temperature range: -60°C to 200°C
Wire and cable manufacturer Linke Cable Technology Co., Ltd is a leading cable supplier in China. In the past over 10 years, Linke Cable has been focusing on R&D, production and marketing of wire and cable. Linke provide various cables&custom cable solutions for all over the world. We are specialized in EV charging cable, medical cable, silicone cable, spring cable, braided cable, towlobe cable, UL wire, automotive cable, etc.
At Linke cable, we believe there's a better way to bring better cables to market. We use an engineer-to-engineer approach to develop better cables for customers and improve the quality of one's life.
We past UL1007,UL1185,UL1672,UL10070,UL10483,UL1015,UL1569,UL10012,UL10269(Single conductor,thermoplastic insulation)
UL2095,UL2129,UL2468,UL2586,UL2725,UL20233,UL20280,UL20963,UL2103,UL2463,UL2517,UL2587,UL2835,UL20276,UL20549,UL21198,2104,UL2464,UL2576,UL2661,UL2919,UL20279,UL20886,UL21664
ISO9001 and ISO13485,TS16949
CNR- Appliance Wiring Material,
Extruded PVC Insulated Single,rated 105ºC,1000V,ClassI,GroupA,B,or AB, FT1 and/or FT2.
Extruded PVC Non-integral Jacketed Cable, rated 105"C, 1000V, Class I, Class or Class I/Il, Group A, B, or AB, FT1 and/or FT2.
Extruded TPU Non-integral Jacketed Cable, rated 80"C, 300V, Class I, Class or Class I/Il, Group A, B, or AB, FT1 and/or FT2
1. Are you a manufacturer or trading company?
We are a professional manufacturer. We can control your order from the first begining to the last.
Welcome to visit us. We'll pick you up in Shenzhen.
2. How can I get a sample to test your quality?
The samples are free for you. New clients are expected to pay for the courier cost.
3. What's your Minimum Order Quantity?
Normally 100m. However, the cable is very heavy.
You'd better order a suitable quantity to avoid the high freight.
Sea transportation is the best option.
4. Can I get a discount?
It depends on your quantity, We can make a discount and afford the freight. Pls kindly contact us.
5. Does your company accept OEM production?
Yes, could print your company name, we even custom the quality card to promote your company