Aerosun 35000L Cgj5450gjj Aircraft Fuelling Aircraft Refuelling Semi-Trailer, Aircraft Refueller, Aircraft Fuelling
| Supplier | Aerosun Corporation |
|---|---|
| Price | $ 225000.00 / Piece |
| Availability | In Stock |
| Mini Order: | 1 Piece |
Purchase details
Payments:
Tax:
Tax Included
Returns & Refunds:
Eligible for refunds within 30 days of receiving products.
returns and refunds
Product detail
Model NO.
CGJ5450GJJ
Seats
6-9
Horsepower
251-350hp
Engine Capacity
>8L
Storage
Oil
Condition
New
Trademark
Aerosun SanLi
Origin
China
HS Code
8705909990
Production Capacity
1000units/Year
Transmission Type:
Automatic
Power:
Diesel
Load Capacity:
21-30t
Emission Standard:
Euro 5
Tank Volume:
>30000L
Drive Wheel:
6×4
Aerosun CGJ5450GJJ Aircraft RefuellerSemi-Trailer
This Aircraft refueller Semi-Trailer is mainly used for pressure refueling and pumping for the aircrafts equipped with pressure refueling connector in airport. The outline picture is shown below.
1 Main functions
Pressure refueling: pressure refuel all kinds of aircrafts or other containers from by its own reel hose or deck hose and pressure refueling connector after filtering and measuring.
Pumping oil: pumping oil from all kinds of aircrafts or other containers to its own oil tank by pressure refueling connector after filtering and measuring.Circulate mix oil in the oil tank.
Loading oil: bottom refuel to its own oil tank by other equipments.
2 Entire vehicle technical specification
Dimension L*W*H, mm 15650×3050×3050Minimum turning diameter, m 24
Curb weight of entire vehicle, kg 16370
Loading weight, Kg 28000
Lifting range of lift platform, m 1750~4250
Lifting time of lift platform 20~25
Rated volume of oil tank, L 35000
Tank material: Aluminum Alloy
3 Performance parameter of refueling system
1) Maximum flow rate of pressure refueling
lReel double-hose refueling, L/min: 2000
lPlatform double-hose refueling, L/min: 2400
2)Maximum flow rate of pumping in vacuum (single hose), L/min
lReel single hose refueling, L/min: 250
lPlatform single hose refueling, L/min: 420
3)Maximum flow rate of refueling, L/min: 1500 (single-hose)/2500 (double-hose)
4)Accuracy of Flow meter: ±0.2%
5)Performance index of filtration must conform to the requirements of API/IP 1581 5th.
6)When refueling, the pressure in the end of the pipeline is 0.35Mpa. When the pressure is over the setting data, it will cut off automatically.
7)2 pieces reel pressure refueling hoses and 2pics platform pressure refueling hoses